3EM13853AF
Issue 01, September 2007
TAP-131
INHSWWKG Alarm
PURPOSE
This procedure provides instructions to clear an INHSWWKG alarm against a DS3, ECC, TMUX, or
VSC card.
GENERAL
INHSWWKG indicates protection switching (automatic and manual) from protect to working is
inhibited.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
Enter
1
Note AID of card with INHSWWKG alarm.
2
Enter
3
where:
AID=Equipment Access Identifier of card with INHSWWKG
Did output return COMPLD or DENY?
4
Enter
5
Did INHSWWKG alarm clear for card?
6
Contact next level of technical support for assistance.
7
8
STOP. This procedure is complete.
INHSWWKG Alarm
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
ALW-SWTOWKG-EQPT::AID;
If COMPLD, go to step 5.
If DENY, go to step 7.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 8.
If no, go to step 7.
to retrieve all alarms and conditions.
for card with INHSWWKG.
to retrieve all alarms and conditions.
TAP-131
4-83