Omron DeviceNet CV Series Operation Manual page 229

Devicenet slaves
Table of Contents

Advertisement

Waterproof Terminals (IP67)
Wiring
CAN H
CAN L
4
5
1
3
DRAIN
V−
2
V+
2
3
1
4
+
I/O power
supply
CAN H
CAN L
4
5
1
3
DRAIN
V−
2
V+
2
3
1
4
+
I/O power
supply
212
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
The following diagram shows the wiring of the DRT1-OD08CL Waterproof
Terminal (NPN).
3 G
2
4
2
NC
NC
Output 0
1
V
1 V
4
2
4
NC
Output
Output 1
3
3
G
The following diagram shows the wiring of the DRT1-OD08CL-1 Waterproof
Terminal (PNP).
3 G
2
4
2
Output 0
NC
NC
1
V
1 V
4
2
4
Output 1
NC
Output
3
3
G
Solenoid
Note External power supply line 0V and output line G are connected internally, as
are external power supply line 24V and output line V. When output power is
supplied to external power supply connectors, power can be supplied to out-
put devices from output lines G and V provided that the total current does not
exceed 2.4 A. If the total current exceeds 2.4 A, the power must not be sup-
plied from the connector; it must be supplied externally instead.
3 G
3 G
4
2
4
NC
Output 2
Output 4
1
V
1
V
1 V
1 V
2
4
2
NC
NC
Output 5
3
G
3
G
Solenoid
3 G
3 G
4
2
4
Output 2
Output 4
NC
1
V
1
V
1 V
1 V
2
4
2
Output 5
NC
NC
3
G
3
G
Section 5-4
3 G
2
4
NC
Output
6
1
V
1 V
4
2
Output
NC
7
3
G
Valve
3 G
2
4
NC
Output
6
1
V
1 V
4
2
NC
Output
7
3
G
Valve

Advertisement