Part 7: Common Reference Material
MR-J3-_T_
No.
Name
MR-J3-D01 input signal device
Po03
selection 2 (CN10-27,28)
MR-J3-D01 input signal device
Po04
selection 3 (CN10-29,30)
MR-J3-D01 input signal device
Po05
selection 4 (CN10-31,32)
MR-J3-D01 input signal device
Po06
selection 5 (CN10-33,34)
MR-J3-D01 input signal device
Po07
selection 6 (CN10-35,36)
MR-J3-D01 output signal device
Po08
selection 1 (CN10-46,47)
MR-J3-D01 output signal device
Po09
selection 2 (CN10-48,49)
Po10 Function selection O-1
Po12 Function selection O-3
Po13 MR-J3-D01 analog monitor output 1
MR-J4-_A_-RJ
Type
Target
No.
_ _ XX
Hex
Po03
XX _ _
_ _ XX
Hex
Po04
XX _ _
_ _ XX
Hex
Po05
XX _ _
_ _ XX
Hex
Po06
XX _ _
_ _ XX
Hex
Po07
XX _ _
_ _ XX
Hex
Po08
XX _ _
_ _ XX
Hex
Po09
XX _ _
_ _ _ X
Hex
_ X _ _
Po10
X _ _ _
_ _ _ X
Hex
Po12
_ _ X _
Hex
_ _ _ X
Po13
7 - 69
Type
Target
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
The setting value will be maintained.
_ _ XX
The setting value will be maintained
regardless of whether conversion of
Hex
the input/output signal assignment
XX _ _
(parameter converter function) is
enabled or disabled.
_ _ _ X
The setting value will be maintained.
Hex
_ X _ _
The setting value will be maintained.
X _ _ _
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
Hex
_ _ X _
The setting value will be maintained.
_ _ _ 0 will be changed to _ _ 00
_ _ _ 1 will be changed to _ _ 01
_ _ _ 2 will be changed to _ _ 02
_ _ _ 3 will be changed to _ _ 03
_ _ _ 4 will be changed to _ _ 04
_ _ _ 5 will be changed to _ _ 0E
_ _ _ 6 will be changed to _ _ 06
Hex
_ _ XX
_ _ _ 7 will be changed to _ _ 07
_ _ _ 8 will be changed to _ _ 08
_ _ _ 9 will be changed to _ _ 09
_ _ _ A will be changed to _ _ 0A
_ _ _ B will be changed to _ _ 0B
_ _ _ C will be changed to _ _ 0C
_ _ _ D will be changed to _ _ 0D
Conversion rule