Part 7: Common Reference Material

6.1.6 How to use the J3 compatibility mode

(1) Setting of the controller
To use in the J3 compatibility mode, select MR-J3 series in the system setting window.
(2) Setting of setup software (SETUP221E)
To use in the J3 compatibility mode, make the system setting as follows.
Cautions for using setup software (SETUP221E)
The gain search cannot be used. You can use the advanced gain search.
(3) Setting of MR Configurator2
To use in the J3 compatibility mode, make the system setting as follows.
Cautions for using MR Configurator2
Use MR Configurator2 with software version 1.12N or later. Older version than 1.12N cannot be used.
Information about existing models (MR-J3) cannot be updated with the parameter setting range
update function. Register a new model to use.
The alarm will be displayed by 3 digits.
The robust disturbance compensation cannot be used.
Operation mode in J3 compatibility mode
MR-J3-B standard control mode (rotary servo motor)
Operation mode in J3 compatibility mode
MR-J3-B standard control mode (rotary servo motor)
Operation mode in J3 compatibility mode
MR-J3-B standard control mode (rotary servo motor)
7 - 138
System setting
Select MR-J3-_B.
System setting
Select MR-J3-_B.
System setting
Select MR-J3-_B.