Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
No.
Name and function
PD04
Input signal automatic ON selection 4
Select the input devices to be automatically turned ON.
0
0
MR-J3-_T_
Signal name
Point table No.selection 1 (DI0)
Point table No.selection 2 (DI1)
Point table No.selection 3 (DI2)
Point table No.selection 4 (DI3)
Signal name
Point table No.selection 5 (DI4)
Point table No.selection 6 (DI5)
Point table No.selection 7 (DI6)
Point table No.selection 8 (DI7)
BIN 0: Used to external input signal.
BIN 1: Automatic ON
Initial
No.
value
0000h
PD42
Input signal automatic on selection 4
Select input devices to turn on them automatically.
_ _ _ x
_ _ _ x (BIN): For manufacturer setting
(HEX)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
Initial value
BIN
HEX
x _ _ _ (BIN): For manufacturer setting
0
_ _ x _
_ _ _ x (BIN): For manufacturer setting
0
0
(HEX)
0
_ _ x _ (BIN): For manufacturer setting
0
_ x _ _ (BIN): For manufacturer setting
Initial value
x _ _ _ (BIN): For manufacturer setting
BIN
HEX
_ x _ _
_ _ _ x (BIN): DI0 (point table No. selection 1)
0
0
(HEX)
0: Disabled (Use for an external input signal.)
0
0
1: Enabled (automatic on)
0
_ _ x _ (BIN): DI1 (point table No. selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI2 (point table No. selection 3)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI3 (point table No. selection 4)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _
_ _ _ x (BIN): DI4 (point table No. selection 5)
(HEX)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI5 (point table No. selection 6)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI6 (point table No. selection 7)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI7 (point table No. selection 8)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
Convert the setting value into hexadecimal as follows.
0
6 - 73
MR-J4-_A_-RJ
Name and function
0
Input device
DI0 (Point table No. selection 1)
DI1 (Point table No. selection 2)
DI2 (Point table No. selection 3)
DI3 (Point table No. selection 4)
Input device
DI4 (Point table No. selection 5)
DI5 (Point table No. selection 6)
DI6 (Point table No. selection 7)
DI7 (Point table No. selection 8)
BIN 0: Use for an external input signal.
BIN 1: Automatic on
Initial
value
0h
0h
0h
0h
Initial value
BIN HEX
0
0
0
0
0
Initial value
BIN HEX
0
0
0
0
0