Download Print this page

Mitsubishi Electric MELSERVO-J4 Series Transition Handbook page 396

Hide thumbs Also See for MELSERVO-J4 Series:

Advertisement

Part 7: Common Reference Material
(3) Electronic dynamic brake
The electronic dynamic brake operates in the initial state for HG series servo motors with a 600 W or
smaller capacity.
The time constant " " for the electronic dynamic brake will be shorter than that for normal dynamic brake.
Therefore, coasting distance will be shorter than in normal dynamic brake.
(a) Parameter settings (for MR-J4-_A_series)
Abbrevia-
No.
tion
PF09
*FOP5
Function selection F-5
Setting digit
_ _ _ x
PF15
DBT
Electronic Dynamic Brake Operating Time
Set an operating time for the electronic dynamic brake. (Note)
(b) Parameter settings (for MR-J4-_B_series/MR-J4W2-_B servo amplifier)
Abbrevia-
No.
tion
PF06
*FOP5
Function selection F-5
Setting digit
_ _ _ x
PF12
DBT
Electronic Dynamic Brake Operating Time
Set an operating time for the electronic dynamic brake. (Note)
Note. When the electronic dynamic brake is released during operation, the servo system cannot be switched on until the PF12 operating
time is over.
Series
HG-KR
HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR
HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR
HG-SR51/HG-SR52
HG-AK
HG-AK0136/HG-AK0236/HG-AK0336
Name and function
Electronic dynamic brake selection.
0: Automatic (effective only for specific servo motors)
2: Disabled
Refer to the following table for the specified servo motors.
Series
HG-KR
HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR
HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR
HG-SR51/HG-SR52
Name and function
Electronic dynamic brake selection.
0: Automatic (effective only for specific servo motors)
2: Disabled
Refer to the following table for the specified servo motors.
Series
HG-KR
HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR
HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR
HG-SR51/HG-SR52
HG-AK
HG-AK0136/HG-AK0236/HG-AK0336
7 - 19
Servo motor
Explanation
Servo motor
Explanation
Servo motor
Initial
Setting
value
range
[unit]
Refer to the
"Name and
Initial
function"
value
column.
0h
2000
0
[ms]
to
10000
Initial
Setting
value
range
[unit]
Refer to the
"Name and
Initial
function"
value
column.
0h
2000
0
[ms]
to
10000

Advertisement

loading

This manual is also suitable for:

Melservo-j3 seriesMelservo-j3w series