Download Print this page

Mitsubishi Electric MELSERVO-J4 Series Transition Handbook page 430

Hide thumbs Also See for MELSERVO-J4 Series:

Advertisement

Part 7: Common Reference Material
2.2.3 Parameter reading from the servo amplifier MR- J3-_A_/MR-J3-_T_
(1) Start MR Configurator2 (SW1DNC-MRC2-E).
For MR Configurator2 (SW1DNC-MRC2-E) of version 1.09K or later, the "MR-J4-A(-RJ) standard"
project is created at the first startup after installation.
(2) Create a new project.
Select [Project] - [New] from the menu to display the New Project dialog box. Select "MR-J3-A" or "MR-
J3-T" for Model.
The setting of "Station" must be the same as that of the servo amplifier. Set the same value as that of
the parameter: [Pr. PC20]. The following figure shows an example of when "MR-J3-A" is selected for
Model.
7 - 53

Advertisement

loading

This manual is also suitable for:

Melservo-j3 seriesMelservo-j3w series