Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
(2) MR-J3-_T_/MR-J4-_A_-RJ (Serial communication operation)
MR-J3-_T_
24 V DC (Note 4, 10)
(Note 3,5) Forced stop
Proximity dog
(Note 9)
(Note 5)
Forward rotation
stroke end
Reverse rotation
stroke end
10 m or less
(Note 8)
(Note 7)
Personal
Setup software
computer
(SETUP221E)
MR-J3USBCBL3M
(Option)
+
Note 1. To prevent an electric shock, always connect the protective earth
(PE) terminal (terminal marked
protective earth (PE) of the control box.
2. Connect the diode in the correct direction. If it is connected
reversely, the servo amplifier or the MR-J3-D01 will be faulty and
will not output signals, disabling the forced stop (EMG) and other
protective circuits.
3. The forced stop switch (normally closed contact) must be installed.
4. Supply 24VDC 10% 150 mA current for interfaces of the servo
amplifier from the outside. 150 mA is the value applicable when
all I/O signals are used. The current capacity can be decreased by
reducing the number of I/O points. Refer to section 3.8.2 (1) of "MR-
J3-_T/MR-J3-D01 Servo Amplifier Instruction Manual" that gives the
current value necessary for the interface."MR-J3-_T/MR-J3-D01
5. When starting operation, always turn on forced stop (EMG) and
Forward/Reverse rotation stroke end (LSP/LSN). (Normally closed
contacts)
6. Trouble (ALM) turns on in normal alarm-free condition.
7. Use MRZJW3-SETUP 211E.
8. Personal computers or parameter modules can also be connected
via the CN3 connector, enabling RS-422 communication.
Note that using the USB communication function (CN5 connector)
prevents the RS-422 communication function (CN3 connector) from
being used, and vice versa. They cannot be used together.
Personal computer
RS-232C/RS-422 conversion cable
Recommended product: Interface cable
To RS-232C connector
or
MR-PRU03
parameter module
EIA568-compliant cable (10BASE-T cable, etc.)
9. For the sink I/O interface. For the source I/O interface, refer to
section 3.8.3 of "MR-J3-_T/MR-J3-D01 Servo Amplifier Instruction
Manual".
10. In this case, select a power supply capacity suitable for the number
of input and output signals used. One 24 V DC power supply can be
used for the input and output signals and the servo amplifier.
MR-J3-_T
CN6
(Note 2)
14
RD
Ready
CN6
RA1
5
DICOM
15
ALM
Malfunction (Note 6)
RA2
17
DOCO M
Home position
16
ZP
EMG
1
RA3
return completion
2
DOG
10 m or less
LSP
3
LSN
4
LZ
Encoder Z-phase pulse
13
(differential line driver)
LZR
26
Encoder A-phase pulse
11
LA
(differential line driver)
24
LAR
12
LB
Encoder B-phase pulse
(differential line driver)
25
LBR
CN5
23
LG
Control common
Plate
SD
(Note 1)
) of the servo amplifier to the
DSV-CABV
(Diatrend)
Servo amplifier
CN3
(Note 9)
(Note 3, 5)
Forced stop 2
Servo-on
Operation mode selection 1
Forward rotation start
Reverse rotation start
Proximity dog
(Note 15)
Forward rotation stroke end
(Note 5)
Reverse rotation stroke end
Point table No. selection 1
Point table No. selection 2
Point table No. selection 3
(Note 18, 19)
Point table No. selection 4
24 V DC (Note 4, 14)
(Note 11) Analog override
Upper limit
setting
±10 V/0% to 200%
Upper limit
(Note 8) Analog torque limit
setting
+10 V/maximum torque
Personal
(Note 9)
computer
MR Configurator2
+
(Note 12)
Short-circuit connector
(Packed with the servo amplifier)
Note 1. To prevent an electric shock, always connect the protective earth
(PE) terminal (marked
earth (PE) of the cabinet.
2. Connect the diode in the correct direction. If it is connected
reversely, the servo amplifier will malfunction and will not output
signals, disabling EM2 (Forced stop 2) and other protective circuits.
3. The forced stop switch (normally closed contact) must be installed.
4. Supply 24 V DC ± 10% to interfaces from outside. The total current
capacity is up to 500 mA. 500 mA is the value applicable when all
I/O signals are used. The current capacity can be decreased by
reducing the number of I/O points. Refer to section 3.9.2 (1) of
"MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual" that gives the
current value necessary for the interface. A 24 V DC power supply
can be used for both input signal and output signal.
5. When starting operation, always turn on EM2 (Forced stop 2), LSP
(Forward rotation stroke end) and LSN (Reverse rotation stroke
end) (normally closed contact).
6. ALM (Malfunction) turns on in normal alarm-free condition (normally
closed contact).
7. The pins with the same signal name are connected in the servo
amplifier.
8. TLA will be available when TL (External torque limit selection) is
enabled with [Pr. PD04], [Pr. PD06], [Pr. PD08], [Pr. PD10], [Pr.
PD12], [Pr. PD14], [Pr. PD18], [Pr. PD20], [Pr. PD22], [Pr. PD44],
and [Pr. PD46]. (Refer to section 3.6.1 (5) of "MR-J4-_A_(-RJ)
Servo Amplifier Instruction Manual".)
9. Use SW1DNC-MRC2-_. (Refer to section 11.7 of "MR-J4-_A_(-RJ)
Servo Amplifier Instruction Manual".)
10. Controllers or parameter units can also be connected via the CN3
connector with the RS-422/RS-485 communication. Note that using
the USB communication function (CN5 connector) prevents the RS-
422 communication function (CN3 connector) from being used, and
vice versa. They cannot be used together.
RS-422
compatible controller
or
MR-PRU03
parameter unit
PRU03
10BASE-T cable, etc. (EIA568-compliant)
11. Use an external power supply when inputting a negative voltage.
6 - 28
MR-J4-_A_-RJ
Servo amplifier
(Note 7)
CN1
24 V DC (Note 4, 14)
46
DOCOM
47
DOCOM
(Note 2)
10 m or shorter
(Note 13)
(Note 7)
48
ALM
RA1
Main circuit
CN1
power supply
22
CPO
EM2
42
RA2
SON
15
23
ZP
RA3
MD0
16
25
MEND
ST1
RA4
17
ST2
18
24
INP
RA5
DOG
45
49
RD
RA6
LSP
43
13
(Note 16)
LSN
44
14
DI0
19
(Note 16)
10 m or shorter
DI1
41
8
LZ
DI2
10
9
LZR
DI3
35
4
LA
DICOM
20
5
LAR
DICOM
21
6
LB
OPC
12
7
LBR
P15R
1
VC
2
34
LG
Control common
LG
28
Encoder Z-phase pulse
33
OP
(open-collector)
Plate
SD
TLA
27
2 m or shorter
SD
Plate
2 m or shorter
(Note 10)
(Note 7)
USB cable
CN6
CN5
(option)
3
MO1
1
LG
2
MO2
CN8
2 m or shorter
(Note 1)
) of the servo amplifier to the protective
Malfunction (Note 6)
Rough match
Home position
return completion
(Note 17)
Travel completion
In-position
Ready
Encoder Z-phase pulse
(differential line driver)
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Control common
Analog monitor 1
± 10 V DC
± 10 V DC
Analog monitor 2
Servo amplifier
CN3