Part 4: Replacement of MR-J3W-_B with MR-J4W2-_B

3.7.3 Comparison of parameter details

No.
Name and function
PA01
Control mode
Turn off the power and then on again after setting the
parameter to validate the parameter value.
Select the control mode.
This parameter is set as "_ _ 0_" in the initial setting.
0 0 x 0:
Control mode selection
0: Rotary servo motor
PA02
Regenerative option
Turn off the power and then on again after setting the
parameter to validate the parameter value.
Wrong setting may cause the regenerative option to burn.
If the regenerative option selected is not for use with the
servo amplifier, [AL. 37 Parameter error] occurs.
The MR-RB3B can be used with the servo amplifier
whose software version is B3 or later.
Set this parameter when using the regenerative option.
For MR-J4W2-0303BN6 servo amplifiers, this digit cannot
be used other than the initial value.
0 0 x x:
Selection of regenerative option
00: Regenerative option is not used (built-in regenerative
resistor is used)
0D: MR-RB14
0E: MR-RB34
10: MR-RB3B
POINT
"x" in the "Setting digit" columns means which digit to set a value.
MR-J3W-_B
Initial
No.
value
0000h
PA01
Operation mode
Select an operation mode.
_ _ _ x:
For manufacturer setting
_ _ x _:
Operation mode selection
0: Standard control mode
Setting other than above will result in [AL. 37 Parameter
error].
For MR-J4W2-0303B6 servo amplifiers, this digit cannot
be used other than the initial value.
_ x _ _
For manufacturer setting
x _ _ _
Compatibility mode selection
To change this digit, use an application software "MR-
J4(W)-B mode selection". When you change it without
the application, [AL. 3E Operation mode error] will occur.
Set the digit as common setting.
0: J3 compatibility mode
1: J4 mode
0000h
PA02
Regenerative option
Select a regenerative option.
Incorrect setting may cause the regenerative option to
burn.
If a selected regenerative option is not for use with the
servo amplifier, [AL. 37 Parameter error] occurs.
For MR-J4W2-0303B6 servo amplifiers, this digit cannot
be used other than the initial value.
_ _ x x:
Regenerative option selection
00: Regenerative option is not used. (Built-in
regenerative resistor is used.)
0B: MR-RB3N
0D: MR-RB14
0E: MR-RB34
10: MR-RB3B (available with servo motors for MR-J3)
_ x _ _
For manufacturer setting
x _ _ _
For manufacturer setting
4 - 26
MR-J4W2-_B
Name and function
Initial
value
0h
0h
0h
1h
00h
0h
0h