Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
(9) Others (Command [0] [0]/[0] [2])
Command Data No.
[0] [0]
[1] [2]
Reading test operation mode
0000: Normal mode (not test operation mode)
0001: JOG operation
0002: Positioning operation
0003: Motorless operation
0004: Output signal (DO) forced output
0005: Single-step feed opera
[0] [2]
[9] [0]
Servo motor-side pulse unit absolute position
[9] [1]
Command unit absolute position
[7] [0]
Software version
MR-J3-_T_
Description
6 - 94
[Pr. PT01]: "1_ _ _"
Frame
Description
length
4
Reading test operation mode
0000: Normal mode (not test operation mode)
0001: JOG operation
0002: Positioning operation
0004: Output signal (DO) forced output
0005: Single-step feed opera
8
Servo motor-side pulse unit absolute position
8
Command unit absolute position
16
Software version
MR-J4-_A_-RJ
Frame
length
16
4
8
8