Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ

3.2 Configuration including auxiliary equipment

(1) MR-J3-_T_ and MR-J3-D01 (DIO command)
The diagram shows MR-J3-100T or less, for 3-phase or 1-phase 200 V to 230 V AC
R S T
(Note 3)
Power supply
Molded-case circuit
breaker (MCCB)
Magnetic
contactor
(MC)
(Note 2)
Line noise
filter
(FR-BSF01)
L
1
L
2
L
3
(Note 2)
Power factor
improving DC
reactor
(FR-BEL)
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P1 and P2.
3. 1-phase 200 V to 230 V AC power supply may be used with the servo amplifier of MR-J3-70T or less.
For 1-phase 200 V to 230 V AC, connect the power supply to L1/L2 and leave L3 open. Refer to "section 3.1 Function
Comparison Table (3)" for the power supply.
Servo amplifier
U
V
W
P
1
P
2
P
C
Regenerative
option
Setup software
(SETUP221E)
CN3
CN5
CN 20
CN10
CN6
CN2
CN4
(Note 1)
Battery
MR-J3BAT
6 - 20
Personal
computer
Analog output
signal
I/O signal
I/O signal
Servo motor