Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
(2) MR-J3-_T_ (Serial communication operation)
The diagram shows MR-J3-100T or less, for 3-phase or 1-phase 200 V to 230 V AC
R S T
(Note 3)
Power supply
Molded-case circuit
breaker (MCCB)
Magnetic
contactor
(MC)
Line noise
filter
(FR-BSF01)
L
1
L
2
L
3
(Note 2)
Power factor
improving DC
reactor
(FR-BEL)
Regenerative option
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using power factor improving DC reactor, short P1 and P2.
3. 1-phase 200 V to 230 V AC power supply may be used with the servo amplifier of MR-J3-70T or less.
For 1-phase 200 V to 230 V AC, connect the power supply to L1/L2 and leave L3 open. Refer to "section 3.1 Function
Comparison Table (3)" for the power supply.
(Note 2)
U
W
P
1
P
2
P
C
Servo amplifier
V
6 - 21
Personal
Setup software
computer
(SETUP221E)
CN5
CN3
CN1
CN6
CN2
CN4
(Note 1)
Battery
MR-J3BAT
Servo motor
I/O signal