2.3.4 Parameters that need to be checked after parameter conversion

(1) MR-J3-_B_ and MR-J3W-_B => MR-J4-_B_ and MR-J4W2-_B
Parameter
No.
PA04
Function selection A-1
PA09
Auto tuning response
PA10
In-position range
PA15
Encoder output pulses
PC03
Encoder output pulse selection
PC11
Analog monitor 1 offset
PC12
Analog monitor 2 offset
Analog monitor feedback position
PC13
output standard data Low
Analog monitor feedback position
PC14
output standard data High
PD15
Driver communication setting
Driver communication setting -
PD16
Master - Transmit data selection 1
Driver communication setting -
PD17
Master - Transmit data selection 2
Driver communication setting -
PD20
Slave - Master axis No. selection 1
Master-slave operation - Torque
PD30
command coefficient on slave
Master-slave operation - Speed limit
PD31
coefficient on slave
Master-slave operation - Speed limit
PD32
adjusted value on slave
Note. For items that have no setting value listed in the table, refer to "Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_",
"Part 4: Review on Replacement of MR-J3W-_B_ with MR-J4W-_B_"..
Name
Initial value
2000h
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Setting
value
Forced stop deceleration function selection
-
To configure the same settings as those for MR-J3-_B_,
select "Forced stop deceleration function disabled (EM1)".
Auto tuning response setting
-
Adjust the gain value again after the replacement.
In-position range
When the setting of MR-J3-_B_ is larger than 4095 pulses,
-
it will be converted into 65535 pulses.
Check for any problems of the equipment.
Encoder output pulses
When the setting of MR-J3-_B_ is larger than 4095 pulses
-
and the output dividing ratio setting is selected, 65535
pulses will be set. Check for any problems of the
equipment.
Encoder output pulse setting selection
To use "_ _4_: Encoder pulse through output setting", use
-
MR-J4-_B_ with the software version A5 or later. A
parameter error will occur when the software version A4 or
earlier is used.
Not converted by the parameter converter function.
-
Set the value as required.
Not converted by the parameter converter function.
-
Set the value as required.
-
Set the value as required.
-
Set the value as required.
Master axis operation selection
Slave axis operation selection
Use MR-J4-_B_ with the software version A8 or later to
-
use this function.
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Use MR-J4-_B_ with the software version A8 or later to
use this function.
-
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Use MR-J4-_B_ with the software version A8 or later to
use this function.
-
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Use MR-J4-_B_ with the software version A8 or later to
use this function.
-
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Use MR-J4-_B_ with the software version A8 or later to
use this function.
-
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Use MR-J4-_B_ with the software version A8 or later to
use this function.
-
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
Use MR-J4-_B_ with the software version A8 or later to
use this function.
-
A parameter error will occur when MR-J4-_B_ with the
software version A7 or earlier is used.
7 - 83