Download Print this page

Mitsubishi Electric MELSERVO-J4 Series Transition Handbook page 326

Hide thumbs Also See for MELSERVO-J4 Series:

Advertisement

Part 6: Review on Replacement of MR-J3-_T_(DIO command/ Serial communication operation) with MR-J4-_A_-RJ
MR-J3-_T_
No.
Name and function
PA05
Feeding function selection
This parameter is made valid when power is switched off,
then on after setting, or when the controller reset has
been performed.
Select the feed length multiplication and the manual pulse
generator input multiplication.
0 _ _ x:
Feed length
multiplication
Setting
Feed unit
value
[ m]
factor (STM)
[times]
0
1
1
1
10
10
2
100
100
3
1000
1000
0 _ x _:
Manual pulse generator multiplication factor
0: 1 time
1: 10 times
2: 100 times
0 x_ _:
Servo motor speed setting unit selection
0: 1 r/min unit
1: 0.1 r/min unit
Setting "1" will display "servo motor speed" in units of 0.1
r/min.
This digit is available with servo amplifier with software
version A4 or later.
0000h
Position data input range [mm]
Absolute value
Incremental value
command system
command system
-999.999 to +999.999
0 to +999.999
-9999.99 to +9999.99
0 to +9999.99
-99999.9 to +99999.9
0 to +99999.9
-999999 to +999999
0 to +999999
Initial
No.
value
PT03
Feeding function selection
_ _ _ x:
Feed length multiplication [STM]
0: × 1
1: × 10
2: × 100
3: × 1000
_ _ x _:
Manual pulse generator multiplication
0: × 1
1: × 10
2: × 100
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
PC29
Function selection C-8
_ _ _ x:
For manufacturer setting
_ _ x _:
Speed command input unit selection
Select the setting units of [Pr. PC05] to [Pr. PC11], [Pr.
PT05], [Pr. PT06], and [Pr. PT13].
0: 1 r/min Unit
1: 0.1 r/min Unit
Setting "1" will display "servo motor speed" in units of 0.1
r/min.
When displaying data recorded with the drive recorder
function, do not change this digit before and after the
recording. Doing so will display the data incorrectly
because the setting unit differs between when the data
was recorded and when the recorded data is displayed.
This digit is available with servo amplifier with software
version B3 or later.
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
6 - 47
MR-J4-_A_-RJ
Name and function
Initial
value
0h
0h
0h
0h
0h
0h
0h
0h

Advertisement

loading

This manual is also suitable for:

Melservo-j3 seriesMelservo-j3w series