Reverse Direction (continued)
Hydraulic System: Hydraulic Flow Diagrams
The traction circuit operates essentially the same in reverse as it does when
moving forward. The primary difference is that the direction of fluid flow through
the circuit is reversed when the bottom of the traction pedal is pushed. The
reverse traction pressure is likewise limited to 280 bar (4,061 psi). Again, the
fluid flowing from the wheel motors will return to the variable displacement pump
and is continuously pumped through the closed loop traction circuit as long as
the traction pedal is pushed. The charge circuit functions the same in reverse as
it does in the forward direction.
Page 5–18
ProLine H800
19241SL Rev A