Toro ProLine H800 Service Manual page 250

Hide thumbs Also See for ProLine H800:
Table of Contents

Advertisement

Charging the Battery
Electrical System: Service and Repairs
To minimize damage to the battery and allow the battery to charge fully, do the
following slow charging procedure. You can do this charging procedure with a
constant current battery charger that is locally available.
Follow the manufacturer's instructions when using a battery charger.
Note: Use specific gravity of the battery cells is the most accurate procedure
of determining the battery condition.
1. Determine the battery charge level from either its specific gravity or open
circuit voltage.
Battery Charge Level
100%
75%
50%
25%
0%
2. Determine the charging time and rate using the manufacturer's battery
charger instructions or the following
Battery Charge Level Table
Battery
Reserve
Capacity
75%
(Minutes)
3.8 hrs
80 or less
5.3 hrs
81 to 125
5.5 hrs
126 to 170
5.8 hrs
171 to 250
6 hrs
above 250
10 A
IMPORTANT
Specific Gravity
1.265
1.225
1.190
1.155
1.120
Battery Charge Level Table (page
Battery Charge Level (Percent of Fully Charged)
50%
7.5 hrs
@
@
3 A
3 A
10.5 hrs
@
@
4 A
4 A
11 hrs
@
@
5 A
5 A
11.5 hrs
@
@
6 A
6 A
12 hrs
@
@
10 A
Page 6–50
Open Circuit Voltage
12.68
12.45
12.24
12.06
11.89
6–50).
25%
0%
11.3 hrs
15 hrs
@
@
3 A
3 A
15.8 hrs
21 hrs
@
@
4 A
4 A
16.5 hrs
22 hrs
@
@
5 A
5 A
17.3 hrs
23 hrs
@
@
6 A
6 A
18 hrs
24 hrs
@
@
10 A
10 A
ProLine H800
19241SL Rev A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3105031050te