Removing the Chute Cleaning Cylinder (continued)
Hydraulic System: Service and Repairs
g294113
1.
Female quick coupler
2.
O-ring
3.
Hose
4.
Cutting deck
Before opening the hydraulic system, operate all the hydraulic
controls to release system pressure and avoid injury from the
pressurized hydraulic fluid; refer to
Hydraulic System (page
4. Disconnect the hydraulic hoses from the fittings in the chute cleaning cylinder
that is to be removed. Allow the hoses to drain into a suitable container.
Remove and discard the O-rings from the fittings.
5. Install clean caps or plugs on the hydraulic hoses and fittings to prevent
contamination.
6. Remove the split pins (item 7 in
chute cleaning cylinder (6) to the levers (4).
7. Remove the chute cleaning cylinder (5) from the cutting deck (1).
8. If the hydraulic fittings are to be removed from the chute cleaning cylinder,
mark the fitting orientation for assembly purposes. Remove the fittings from
the chute cleaning cylinder and discard the O-rings from the fittings.
Figure 99
5.
Hydraulic cylinder
6.
O-ring
7.
Bolt
CAUTION
Releasing Pressure from the
5–5).
Figure
98) and pins (5) that secures the
Page 5–128