Replacement Procedure
Level Vernier Module Replacement (A3)
Level Vernier Module Replacement (A3)
Tools Required
•
•
•
•
•
Removal Procedure
Refer to
Step 1. Remove the outer cover as described in
Step 2. Remove the front panel as described in
Step 3. Disconnect the semi-rigid cable (item 1).
Step 4. Disconnect the semi-rigid cable (item 2).
Step 5. Remove a TORX T10 screw fastening the module to the bottom. (item 3)
Step 6. Slide the level vernier module.
236
TORX screwdriver, T10, T15, and T20
Flat edge screwdriver
Open-end wrench, 5/8 inch
Open-end torque wrench, 5/16 inch or 8mm (set to 1.08 N-m / 9.5 lb-in)
(for reconnecting SMA connector)
Torque driver set, 5/16 inch (set to 1.08 N-m / 9.5 lb-in) (for reconnecting
SMA connector)
Figure 6-23
for this procedure.
"Outer Cover Removal" on page
"Front Panel Removal" on page
Keysight E5071C ENA Network Analyzers
203.
204.