Sign In
Upload
Manuals
Brands
Keysight Manuals
Measuring Instruments
E4980A
Keysight E4980A Manuals
Manuals and User Guides for Keysight E4980A. We have
4
Keysight E4980A manuals available for free PDF download: User Manual, Service Manual, Technical Overview
Keysight E4980A User Manual (529 pages)
Precision LCR Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 8.67 MB
Table of Contents
Table of Contents
3
Unpacking and Preparation
17
Contents of this Chapter
17
Checking the Shipment
18
Preparations before Use
20
Verifying the Power Supply
20
Setting up the Fuse
20
Verifying and Connecting the Power Cable
21
How to Remove the Handle
23
Caution When Using the Handle
24
Environmental Requirements
25
Operating Environments
25
Ventilation Requirements
26
Protection against Electrostatic Discharge (ESD)
27
Ensuring Adequate Free Space Around the LCR Meter for Immediate Disconnection of the Power Cable in Case of Emergency
27
Starting the E4980A/AL
28
Turning the Power on and off
28
Disconnecting from the Supply Source
29
Overview
31
Product Introduction
31
Front Panel: Names and Functions of Parts
32
Power Switch
33
Lcd
33
Softkeys
33
Menu Keys
33
Cursor Keys
33
Entry Keys
34
LED Indicator
34
Preset Key
34
Trigger Key
34
DC Bias Key
34
DC Source Key
34
UNKNOWN Terminals
35
Front USB Port
35
Ground Terminal
36
DC Source Terminal
36
Rear Panel: Names and Functions of Parts
37
GPIB Interface Connector
37
Interface Connector
37
USB (USBTMC) Interface Port
38
LAN Port
38
External Trigger Input Connector
38
Serial Number Plate
38
Power Cable Receptacle (to LINE)
39
Fan
39
Screen Area: Names and Functions of Parts
40
Display
40
Comment Line Area
40
Softkey Area
41
Measurement Data/Conditions Area
41
Input Line Area
42
System Message Area
42
Status Display Area
42
Basic Operation
43
How to Use Cursor Keys
43
How to Use Skip Keys
44
Display Format
45
MEAS DISPLAY Page
45
Measurement Function
47
Impedance Range
51
Test Frequency
58
Test Signal Level
61
DC Bias
64
Measurement Time Mode
68
Display Setting for Measurement Results
69
Displaying Errors Instead of Measurement Results
71
Monitor Information
75
BIN NO. DISPLAY Page
76
Comparator Function ON/OFF
77
BIN COUNT DISPLAY Page
79
Counter Function
81
LIST SWEEP DISPLAY Page
82
Sweep Mode
84
DISPLAY BLANK Page
86
Configuring Measurement Conditions (Display and Function Related Settings)
87
Initializing the Instrument
87
MEAS SETUP Page
88
Comment Line
90
Trigger Mode
91
Automatic Level Control
93
DC Bias Current Isolation
97
Averaging Factor
98
Trigger Delay Time
99
Step Delay Time
101
DC Bias Voltage Monitor
103
DC Bias Current Monitor
104
DCR Range
105
DCI Range
106
DC Source
107
Automatic Bias Polarity Control
108
Deviation Measurement
110
CORRECTION Page
112
To Set the Correction Function to on or off
113
The Correction Functions of the E4980A/AL Are Operated as Follows
114
Open Correction
115
Short Correction
119
Correction Based on User-Specified Frequency Points
121
Relationships between Correction Based on All Frequency Points and Correction Based on Specified Frequency Points
128
Reading/Writing Correction Data
130
Measurement Functions for the Standard
131
Selecting Single/Multiple Correction Mode
132
Selecting the Cable Length
133
LIMIT TABLE SETUP Page
134
Parameter Swap Feature
135
Comparator Limit Mode
137
Tolerance Mode Nominal Value
139
Turning On/Off the Comparator
140
Turning On/Off the Auxiliary bin
141
Beep Feature
143
Lower and Upper Limits
144
LIST SWEEP SETUP Page
147
Sweep Mode
148
List Sweep Parameters
149
Sweep Points and Limit Modes
150
Sweep Parameter Auto-Completion
153
System Configurations
155
SYSTEM INFO Page
155
Handler Interface
156
Scanner Interface
157
Monitor Information
157
SYSTEM CONFIG Page
158
Turning On/Off the Beep Feature
159
Changing the Beep Tone
160
Changing the Beep Tone
161
Configuring the System Date
161
Configuring the GPIB Address
163
Configuring the LAN IP Address
164
SELF TEST Page
166
Choosing a Test Item
167
SERVICE Page
168
Monitor Information
169
Saving the System Information into External Memory
169
Save/Recall
171
Overview of Save/Recall Functionality
171
Save Methods and Their Uses
171
Folder/File Structure on USB Memory
172
USB Memory Notes
173
Saving/Recalling Instrument Configuration States
174
Overview of Instrument Configurations
174
Medium Mode
175
Choosing a Register Number
176
Memory Status Information
176
Comment Information
177
Saving/Recalling Instrument Configuration States Into/From the Internal Memory
177
Saving/Recalling Instrument Configuration States Into/From USB Memory
179
Using the Auto Recall Feature
181
Saving Measurement Results into USB Memory
182
Measurement Result Format
182
To Save Measurement Results into USB Memory
185
How to Save the Measurement Result of List Sweep Measurement to USB Memory
186
Saving a Screenshot into USB Memory
188
To Save a Screenshot into USB Memory
188
Measurement Procedure and Examples
189
Basic Measurement Procedure
189
Impedance Parameters
191
Parallel/Series Circuit Mode
194
Selecting Circuit Mode of Capacitance
195
Selecting Circuit Mode of Inductance
196
Test Signal Level
197
Test Signal Level Across the DUT
197
Test Signal Level Setting
198
Four-Terminal Pair Configuration
199
Measurement Contacts
201
Capacitance to Ground
201
Contact Resistance
203
Extending Test Leads
204
Guarding for Measurement of Low Capacitance Values
206
Shielding
207
Correction Functions
208
Performing OPEN Correction
210
Performing SHORT Correction
210
Performing LOAD Correction
210
Parasitics Incident to DUT Connection
212
Characteristics Example
213
Capacitor Measurements
215
Inductance Measurements
218
Measurements Using DC Source
221
Overview of Remote Control
225
Types of Remote Control System
225
GPIB Remote Control System
226
What Is GPIB
226
System Configuration
226
Device Selector
227
LAN Remote Control System
228
System Configuration
228
Control over SICL-LAN Server
230
Control over Telnet Server
234
Control Via Web Server
237
USB Remote Control System
240
System Configuration
240
Sending SCPI Command Messages
246
Types and Structure of Commands
246
Grammar of Messages
247
Remote Mode
248
Trigger System
249
System-Wide States and Transitions
249
Data Buffer Memory
255
When Data Buffer Memory Is Used
256
Output Format of Data Buffer Memory
258
Starting a Measurement Cycle (Triggering the Instrument)
260
Configuring the Instrument to Automatically Perform Continuous Measurement
260
Starting Measurement on Demand
260
Waiting for the End of Measurement
262
Using the Status Register
262
Data Transfer
264
Data Format
264
Status Byte
270
Enabling the Status Byte
272
Operation Status Register Structure
273
Standard Event Status Register
276
Enabling the Event Status Register
279
Sample Program
281
Set up Measurement Conditions and LCD Display
281
Detecting End of Measurement
286
Read Measurement Results
290
Read Measurement Data in ASCII Format (Comparator)
290
Read Measurement Data in ASCII Format (Data Buffer Memory)
293
Read Measurement Data in ASCII Format (List Sweep)
296
Read Measurement Data in BINARY (Comparator)
299
Read Measurement Data in BINARY Format (Data Buffer Memory)
303
Read Measurement Data in BINARY Format (List Sweep)
306
Save/Recall
309
Read/Write Correction Data at Specified Frequency Points
312
SCPI Command Reference
319
Notational Conventions in this Command Reference
320
Syntax
320
Description
320
Parameters
320
Equivalent Key
321
E4980A/AL Commands
322
Cls
322
Ese
322
Esr
322
Idn
323
Lrn
323
Opc
323
Opt
323
Rst
323
Sre
324
Stb
324
Trg
324
Tst
324
Wai
325
Abort
325
Amplitude:alc
325
Aperture
325
Bias:current[:Level]
326
Bias:polarity:auto
327
Bias:polarity:current[:Level]
327
Bias:polarity:voltage[:Level]
327
Bias:range:auto
327
Bias:state
328
Bias:voltage[:Level]
328
Comparator:abin
329
Comparator:beeper
329
Comparator:bin:clear
330
Comparator:bin:count:clear
330
Comparator:bin:count:data
330
Comparator:bin:count[:State]
330
Comparator:mode
331
Comparator:sequence:bin
331
Comparator:slimit
332
Comparator[:State]
332
Comparator:swap
333
Comparator:tolerance:bin[1-9]
333
Comparator:tolerance:nominal
334
Control:cbias:state
334
Control:handler:state
334
Control:scanner:state
335
Correction:length
335
Correction:load:state
336
Correction:load:type
336
Correction:method
337
Correction:open[:Execute]
338
Correction:open:state
338
Correction:short[:Execute]
338
Correction:short:state
338
Correction:spot[1-201]:Frequency
339
Correction:spot[1-201]:Load[:Execute]
339
Correction:spot[1-201]:Load:standard
339
Correction:spot[1-201]:Open[:Execute]
340
Correction:spot[1-201]:Short[:Execute]
340
Correction:spot[1-201]:State
340
Correction:use[:Channel]
341
Correction:use:data[:Multi]
341
Correction:use:data:single
342
Current[:Level]
343
Display:cclear
343
Display:enable
343
Display:line
344
Display:page
344
Display[:Window]:Text[1-2][:DATA]:FMSD:DATA
345
Display[:Window]:Text[1-2][:Data]:Fmsd[:State]
346
Fetch[:Impedance]:Corrected
346
Fetch[:Impedance][:Formatted]
346
Fetch:smonitor:iac
347
Fetch:smonitor:IDC
347
Fetch:smonitor:vac
347
Fetch:smonitor:VDC
347
Format:ascii:long
347
Format:border
348
Format[:Data]
348
Format:exponent:digit
349
Frequency[:Cw]
349
Function:dcresistance:range:auto
350
Function:dcresistance:range[:Value]
350
Function:dev[1-2]:MODE
350
Function:dev[1-2]:Reference:fill
351
Function:dev[1-2]:Reference[:Value]
351
Function:impedance:range:auto
352
Function:impedance:range[:Value]
352
Function:impedance[:Type]
353
Function:smonitor:iac[:State]
354
Function:smonitor:IDC[:State]
354
Function:smonitor:vac[:State]
355
Function:smonitor:VDC[:State]
355
Hcopy:sdump:data
356
Initiate:continuous
356
Initiate[:Immediate]
357
List:band[1-201]
357
List:bias:current
358
List:bias:voltage
358
List:clear:all
358
List:current
359
List:dcsource:voltage
359
List:frequency
360
List:mode
360
List:sequence:tstamp:clear
360
List:sequence:tstamp:data
361
List:stimulus:data
361
List:stimulus:mdata
362
List:stimulus:type
362
List:voltage
363
Memory:clear
363
Memory:DIM
364
Memory:fill
364
Memory:read
364
Mmemory:delete[:Register]
365
Mmemory:load:state[:Register]
365
Mmemory:store:state[:Register]
365
Output:DC:isolation:level:auto
366
Output:DC:isolation:level:value
366
Output:DC:isolation[:State]
367
Output:hpower
367
Source:dcsource:state
367
Source:dcsource:voltage[:Level]
368
Status:operation:condition
368
Status:operation:enable
369
Status:operation[:Event]
369
System:beeper[:Immediate]
369
System:beeper:state
369
System:beeper:tone
370
System:communicate:gpib[:Self]:Address
370
System:communicate:lan[:Self]:Address
371
System:communicate:lan[:Self]:Aip[:State]
371
System:communicate:lan[:Self]:Configure
372
System:communicate:lan[:Self]:Control
372
System:communicate:lan[:Self]:Current:address
372
System:communicate:lan[:Self]:Current:dgateway
372
System:communicate:lan[:Self]:Current:smask
373
System:communicate:lan[:Self]:Dgateway
373
System:communicate:lan[:Self]:Dhcp[:State]
373
System:communicate:lan[:Self]:Mac
374
System:communicate:lan[:Self]:Preset
374
System:communicate:lan[:Self]:Restart
374
System:communicate:lan[:Self]:Smask
374
System:date
375
System:error[:Next]
376
System:klock
376
System:persona:manufacturer[:Name]
376
System:persona:manufacturer:default
376
System:preset
377
System:restart
377
Advertisement
Keysight E4980A User Manual (519 pages)
Precision LCR Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 11.04 MB
Table of Contents
Table of Contents
3
Unpacking and Preparation
17
Contents of this Chapter
17
Checking the Shipment
18
Preparations before Use
21
Verifying the Power Supply
21
Setting up the Fuse
21
Verifying and Connecting the Power Cable
22
How to Remove the Handle
24
Caution When Using the Handle
25
Environmental Requirements
26
Operating Environments
26
Ventilation Requirements
27
Protection against Electrostatic Discharge (ESD)
28
Ensuring Adequate Free Space Around the LCR Meter for Immediate Disconnection of the Power Cable in Case of Emergency
28
Starting the E4980A/AL
29
Turning the Power on and off
29
Disconnecting from the Supply Source
30
Overview
31
Product Introduction
31
Front Panel: Names and Functions of Parts
32
Power Switch
33
Lcd
33
Softkeys
33
Menu Keys
33
Cursor Keys
33
Entry Keys
34
LED Indicator
34
Preset Key
34
Trigger Key
34
DC Bias Key
34
DC Source Key
34
UNKNOWN Terminals
35
Front USB Port
35
Ground Terminal
36
DC Source Terminal
36
Rear Panel: Names and Functions of Parts
37
GPIB Interface Connector
37
Interface Connector
37
USB (USBTMC) Interface Port
38
LAN Port
38
External Trigger Input Connector
38
Serial Number Plate
38
Power Cable Receptacle (to LINE)
39
Fan
39
Screen Area: Names and Functions of Parts
40
Display
40
Comment Line Area
40
Softkey Area
41
Measurement Data/Conditions Area
41
Input Line Area
42
System Message Area
42
Status Display Area
42
Basic Operation
43
How to Use Cursor Keys
43
How to Use Skip Keys
44
Display Format
45
MEAS DISPLAY Page
45
Measurement Function
47
Impedance Range
51
Test Frequency
58
Test Signal Level
61
DC Bias
64
Measurement Time Mode
68
Display Setting for Measurement Results
69
Displaying Errors Instead of Measurement Results
71
Monitor Information
75
BIN NO. DISPLAY Page
76
Comparator Function ON/OFF
77
BIN COUNT DISPLAY Page
79
Counter Function
81
LIST SWEEP DISPLAY Page
82
Sweep Mode
84
DISPLAY BLANK Page
86
Configuring Measurement Conditions (Display and Function Related Settings)
87
Initializing the Instrument
87
MEAS SETUP Page
88
Comment Line
90
Trigger Mode
91
Automatic Level Control
93
DC Bias Current Isolation
97
Averaging Factor
98
Trigger Delay Time
99
Step Delay Time
101
DC Bias Voltage Monitor
103
DC Bias Current Monitor
104
DCR Range
105
DCI Range
106
DC Source
107
Automatic Bias Polarity Control
108
Deviation Measurement
110
CORRECTION Page
112
To Set the Correction Function to on or off
113
The Correction Functions of the E4980A/AL Are Operated as Follows
114
Open Correction
115
Short Correction
118
Correction Based on User-Specified Frequency Points
119
Relationships between Correction Based on All Frequency Points and Correction Based on Specified Frequency Points
123
Reading/Writing Correction Data
126
Measurement Functions for the Standard
127
Selecting Single/Multiple Correction Mode
128
Selecting the Cable Length
129
LIMIT TABLE SETUP Page
130
Parameter Swap Feature
131
Comparator Limit Mode
133
Tolerance Mode Nominal Value
135
Turning On/Off the Comparator
136
Turning On/Off the Auxiliary bin
137
Beep Feature
139
Lower and Upper Limits
140
LIST SWEEP SETUP Page
143
Sweep Mode
144
List Sweep Parameters
145
Sweep Points and Limit Modes
146
Sweep Parameter Auto-Completion
149
System Configurations
151
SYSTEM INFO Page
151
Handler Interface
152
Scanner Interface
153
Monitor Information
153
SYSTEM CONFIG Page
154
Turning On/Off the Beep Feature
155
Changing the Beep Tone
156
Changing the Beep Tone
157
Configuring the System Date
157
Configuring the GPIB Address
159
Configuring the LAN IP Address
160
SELF TEST Page
162
Choosing a Test Item
163
SERVICE Page
164
Monitor Information
165
Saving the System Information into External Memory
165
Save/Recall
167
Overview of Save/Recall Functionality
167
Save Methods and Their Uses
167
Folder/File Structure on USB Memory
168
USB Memory Notes
169
Saving/Recalling Instrument Configuration States
170
Overview of Instrument Configurations
170
Medium Mode
171
Choosing a Register Number
172
Memory Status Information
172
Comment Information
173
Saving/Recalling Instrument Configuration States Into/From the Internal Memory
173
Saving/Recalling Instrument Configuration States Into/From USB Memory
175
Using the Auto Recall Feature
177
Saving Measurement Results into USB Memory
178
Measurement Result Format
178
To Save Measurement Results into USB Memory
181
How to Save the Measurement Result of List Sweep Measurement to USB Memory
182
Saving a Screenshot into USB Memory
184
To Save a Screenshot into USB Memory
184
Measurement Procedure and Examples
185
Basic Measurement Procedure
185
Impedance Parameters
187
Parallel/Series Circuit Mode
190
Selecting Circuit Mode of Capacitance
191
Selecting Circuit Mode of Inductance
192
Test Signal Level
193
Test Signal Level Across the DUT
193
Test Signal Level Setting
194
Four-Terminal Pair Configuration
195
Measurement Contacts
197
Capacitance to Ground
197
Contact Resistance
199
Extending Test Leads
200
Guarding for Measurement of Low Capacitance Values
202
Shielding
203
Correction Functions
204
Performing OPEN Correction
206
Performing SHORT Correction
206
Performing LOAD Correction
206
Parasitics Incident to DUT Connection
208
Characteristics Example
209
Capacitor Measurements
211
Inductance Measurements
214
Measurements Using DC Source
217
Overview of Remote Control
221
Types of Remote Control System
221
GPIB Remote Control System
222
What Is GPIB
222
System Configuration
222
Device Selector
223
LAN Remote Control System
224
System Configuration
224
Control over SICL-LAN Server
226
Control over Telnet Server
230
Control Via Web Server
233
USB Remote Control System
236
System Configuration
236
Sending SCPI Command Messages
242
Types and Structure of Commands
242
Grammar of Messages
243
Remote Mode
244
Trigger System
245
System-Wide States and Transitions
245
Data Buffer Memory
251
When Data Buffer Memory Is Used
252
Output Format of Data Buffer Memory
254
Starting a Measurement Cycle (Triggering the Instrument)
256
Configuring the Instrument to Automatically Perform Continuous Measurement
256
Starting Measurement on Demand
256
Waiting for the End of Measurement
258
Using the Status Register
258
Data Transfer
260
Data Format
260
Status Byte
266
Enabling the Status Byte
268
Operation Status Register Structure
269
Standard Event Status Register
272
Enabling the Event Status Register
275
Sample Program
277
Set up Measurement Conditions and LCD Display
277
Detecting End of Measurement
282
Read Measurement Results
286
Read Measurement Data in ASCII Format (Comparator)
286
Read Measurement Data in ASCII Format (Data Buffer Memory)
289
Read Measurement Data in ASCII Format (List Sweep)
292
Read Measurement Data in BINARY (Comparator)
295
Read Measurement Data in BINARY Format (Data Buffer Memory)
299
Read Measurement Data in BINARY Format (List Sweep)
302
Save/Recall
305
Read/Write Correction Data at Specified Frequency Points
308
SCPI Command Reference
315
Notational Conventions in this Command Reference
316
Syntax
316
Description
316
Parameters
316
Equivalent Key
317
E4980A/AL Commands
318
Cls
318
Ese
318
Esr
318
Idn
319
Lrn
319
Opc
319
Opt
319
Rst
319
Sre
320
Stb
320
Trg
320
Tst
320
Wai
321
Abort
321
Amplitude:alc
321
Aperture
321
Bias:current[:Level]
322
Bias:polarity:auto
323
Bias:polarity:current[:Level]
323
Bias:polarity:voltage[:Level]
323
Bias:range:auto
323
Bias:state
324
Bias:voltage[:Level]
324
Comparator:abin
325
Comparator:beeper
325
Comparator:bin:clear
326
Comparator:bin:count:clear
326
Comparator:bin:count:data
326
Comparator:bin:count[:State]
326
Comparator:mode
327
Comparator:sequence:bin
327
Comparator:slimit
328
Comparator[:State]
328
Comparator:swap
329
Comparator:tolerance:bin[1-9]
329
Comparator:tolerance:nominal
330
Control:cbias:state
330
Control:handler:state
330
Control:scanner:state
331
Correction:length
331
Correction:load:state
332
Correction:load:type
332
Correction:method
333
Correction:open:state
334
Correction:short[:Execute]
334
Correction:short:state
334
Correction:open[:Execute]
334
Correction:spot[1-201]:Frequency
335
Correction:spot[1-201]:Load[:Execute]
335
Correction:spot[1-201]:Load:standard
335
Correction:spot[1-201]:Open[:Execute]
336
Correction:spot[1-201]:Short[:Execute]
336
Correction:spot[1-201]:State
336
Correction:use[:Channel]
337
Correction:use:data[:Multi]
337
Correction:use:data:single
338
Current[:Level]
339
Display:cclear
339
Display:enable
339
Display:line
340
Display:page
340
Display[:Window]:Text[1-2][:DATA]:FMSD:DATA
341
Display[:Window]:Text[1-2][:Data]:Fmsd[:State]
342
Fetch[:Impedance]:Corrected
342
Fetch[:Impedance][:Formatted]
342
Fetch:smonitor:iac
343
Fetch:smonitor:IDC
343
Fetch:smonitor:vac
343
Fetch:smonitor:VDC
343
Format:ascii:long
343
Format:border
344
Format[:Data]
344
Frequency[:Cw]
345
Function:dcresistance:range:auto
345
Function:dcresistance:range[:Value]
346
Function:dev[1-2]:MODE
346
Function:dev[1-2]:Reference:fill
347
Function:dev[1-2]:Reference[:Value]
347
Function:impedance:range:auto
347
Function:impedance:range[:Value]
348
Function:impedance[:Type]
348
Function:smonitor:iac[:State]
349
Function:smonitor:IDC[:State]
350
Function:smonitor:vac[:State]
350
Function:smonitor:VDC[:State]
351
Hcopy:sdump:data
351
Initiate:continuous
352
Initiate[:Immediate]
352
List:band[1-201]
352
List:bias:current
353
List:bias:voltage
354
List:clear:all
354
List:current
354
List:dcsource:voltage
355
List:frequency
355
List:mode
356
List:sequence:tstamp:clear
356
List:sequence:tstamp:data
356
List:stimulus:data
357
List:stimulus:mdata
357
List:stimulus:type
357
List:voltage
358
Memory:clear
359
Memory:DIM
359
Memory:fill
360
Memory:read
360
Mmemory:delete[:Register]
360
Mmemory:load:state[:Register]
360
Mmemory:store:state[:Register]
361
Output:DC:isolation:level:auto
361
Output:DC:isolation:level:value
362
Output:DC:isolation[:State]
362
Output:hpower
362
Source:dcsource:state
363
Source:dcsource:voltage[:Level]
363
Status:operation:condition
364
Status:operation:enable
364
Status:operation[:Event]
364
System:beeper[:Immediate]
365
System:beeper:state
365
System:beeper:tone
365
System:communicate:gpib[:Self]:Address
366
System:communicate:lan[:Self]:Address
366
System:communicate:lan[:Self]:Aip[:State]
366
System:communicate:lan[:Self]:Configure
367
System:communicate:lan[:Self]:Control
367
System:communicate:lan[:Self]:Current:address
368
Keysight E4980A Service Manual (137 pages)
Precision LCR Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 5.39 MB
Table of Contents
Safety Notices
2
Table of Contents
3
Caution
3
Safety Summary
3
Manufacturer's Declaration
4
Regulatory Compliance Information
4
Safety Notice Supplement
5
General Safety Precautions
6
Safety Symbols
7
Certification
7
Documentation Warranty
8
Exclusive Remedies
8
Assistance
8
Manuals for E4980A/E4980AL
9
Installation Guide
9
Service Guide
9
Table of Contents
11
General Information Organization of Service Guide
17
Instruments Covered by this Manual
19
Required Equipment
20
Performance Test
21
Introduction
21
Test Equipment Required
22
Individual Test Description
23
Frequency Accuracy Test
23
DC Source Level Accuracy Test
23
DC Bias Level Accuracy Test
23
DC Bias V Level Monitor Accuracy Test
23
DC Bias I Level Monitor Accuracy Test
23
AC Signal Level Monitor Accuracy Test
23
AC Signal Level Accuracy Test
24
Impedance Measurement Accuracy Test
24
DCR Measurement Accuracy Test
24
Adjustment
25
Safety Considerations
25
Warm-Up for Adjustment
25
Required Equipment
25
Required Adjustment after Replacing Assembly
26
Writing ID
26
Write Null Phase Track Default Data
26
Null DC Offset Adjustment
26
Null ADC DC Offset Adjustment
26
ADC Linearity Adjustment
26
DC Bias Adjustment
27
DC Level V Monitor Adjustment
27
DC Level I Monitor Adjustment
27
DC Source Adjustment
27
DCR Adjustment
27
Impedance Adjustment
27
AC Level Monitor Adjustment
27
OSC Level Adjustment
27
Troubleshooting
29
Introduction
29
To Troubleshoot the Instrument
30
Primary Trouble Isolation
30
Power on Sequence Troubleshooting
32
Check the Line Voltage and Fuse
32
Check the Power Supply Unit Output
32
Check Booting Process
35
Troubleshooting Using Service Function
36
Power on Test
36
Contents of the Power on Test Results
36
Self Test
36
SERVICE Page
39
Power on Test / Self Test Failure Troubleshooting
43
Function Specific Troubleshooting
47
To Check the Front Panel
48
To Check the LCD
48
To Check the Front USB Port
49
To Check the External Trigger Input
49
To Check the LAN
50
To Check the GPIB
52
To Check the USB (USBTMC) Interface Card
52
To Check the Handler Interface Function (Option 201 Only)
52
To Check the Scanner Interface Function (Option 301 Only)
57
To Check the Bias Current Interface Function (Option 002 Only)
60
Performance Test Failure Troubleshooting
65
Recommended Adjustment for Performance Test Failure
65
Adjustment Failure Troubleshooting
66
Performance Test Failure Troubleshooting
67
Replaceable Parts
69
Replacement Procedure
71
Replacing an Assembly
71
Required Tools
72
3/4 Rack Module Top Replacement
73
Tools Required
73
Removal Procedure
73
Replacement Procedure
73
A3 Analog Daughter Board Replacement
77
Tools Required
77
Removal Procedure
77
Replacement Procedure
77
A2 Analog Board Replacement
79
Tools Required
79
Removal Procedure
79
Replacement Procedure
79
Front Panel Assembly Removal
81
Tools Required
81
Removal Procedure
81
Replacement Procedure
81
Option Interface Replacement
82
Tools Required
82
Removal Procedure
82
Replacement Procedure
82
PPMC PCA Replacement
84
Tools Required
84
Removal Procedure
84
Replacement Procedure
84
A1 Mother Board Replacement
86
Tools Required
86
Removal Procedure
86
Replacement Procedure
86
Power Supply Assembly Replacement
88
Tools Required
88
Removal Procedure
88
Replacement Procedure
89
Base Plate Replacement
91
Tools Required
91
Removal Procedure
91
Replacement Procedure
92
Rear Panel Assembly Replacement
94
Tools Required
94
Removal Procedure
94
Replacement Procedure
95
FAN Assembly Replacement
96
Tools Required
96
Removal Procedure
96
Replacement Procedure
96
GPIB Cable Replacement
98
Tools Required
98
Removal Procedure
98
Replacement Procedure
98
Advertisement
Keysight E4980A Technical Overview (28 pages)
Migrating from a LCR Meter to a Precision LCR Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 0.83 MB
Table of Contents
Table of Contents
2
E4980A Precision LCR Meter Overview
3
Advantages of the E4980A
4
Accuracy
4
Speed
6
Versatility
9
E4980A and 4284A Common Features
12
Migrating from the 4284A
13
Appendix
14
Specification Comparison
14
Setup Resolution Comparison
15
Measurement Speed Comparison
16
Option Configuration Comparison
17
Interface Comparison Table
17
Display Area Design Comparison
18
Front Panel Comparison
19
Menu and Key Tree Structure Comparison
20
Remote Control: GPIB Commands Compatibility
22
Trigger System and Data Transfer Comparison
24
Status Byte Assignments Comparison
25
Technical Reference for the Handler Interface Migration
26
Advertisement
Related Products
Keysight E4980AAL
Keysight E4981A
Keysight E4980AL
Keysight E4982A
Keysight E4981A/001
Keysight E4981A/002
Keysight E4980AL/052
Keysight E4980AL/032
Keysight E4980AL/102
Keysight E4991B
Keysight Categories
Measuring Instruments
Test Equipment
Multimeter
Control Unit
Portable Generator
More Keysight Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL