9.1.2 Parameters
This section contains a tables of parameters.
Note: Do not change the following parameters from the factory settings.
• Reserved parameters
• Parameters not described in this manual
Parameter
Size
No.
2
Basic Function Select Switch 0
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn000
2
Application Function Select Switch 1
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn001
When you turn the power supplies OFF and ON again to enable new settings, turn the
control power supplies to the multi-winding drive unit, SERVOPACKs, and converters
OFF and ON again at the same time.
Setting
Name
Range
0000 to
00B3
Direction Selection
0
Sets CCW as forward direction.
1
Sets CW as forward direction. (Reverse Rotation Mode)
2 or 3
Reserved (Do not use.)
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
0000 to 1122
Servomotor Power OFF or Alarm Gr.1 Stop Mode
0
Stops the servomotor by applying DB (dynamic brake).
1
Stops the servomotor by applying DB and then releases DB.
2
Makes the servomotor coast to a stop state without using the DB.
Overtravel (OT) Stop Mode
0
Stops in accordance with the setting of Pn001.0.
1
Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to servolock state.
2
Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to coasting state.
Converter Selection
0
Sets the standard combination converter (SGDV-COA).
1
Sets a SERVOPACK with a converter that is not the standard combination converter.
A DC power supply is input between the P and N terminals.
Reserved (Do not change.)
Factory
When
Units
Setting
Enabled
−
0000
After restart
−
0000
After restart
9.1 List of Parameters
Classi-
Reference
fication
Section
−
Setup
Reference
Section
4.3.1
−
Setup
Reference
Section
4.3.5
Reference
Section
4.3.2
Reference
Section
−
9
9-3