5 Adjustments
5.2.2 Procedure for Calculating the Moment of Inertia
(1) Operating Procedure
Step
1
2
3
3-1
4
5
6
5-12
Display after Operation
Status Display
 STROKE (Travel Distance) Setting
The travel distance setting range is from -99,990,000 to +99,990,000 [reference units].
Specify the STROKE (travel distance) in increments of 1,000 reference units.
The negative (-) direction is for reverse rotation, and the positive (+) direction is for forward rotation.
Initial value: About 3 rotations
Note 1. Set the number of motor rotations to at least 0.5.
If you do not, "Error" will be displayed and the travel distance cannot be set.
2. To calculate the moment of inertia accurately, it is recommended to set the number of motor rotations
to around 3.
Display example:
After the moment of inertia is
calculated.
Keys
Press the
Key to view the main menu for the util-
ity function mode. Use the
through the list, and select Fn201.
Press the
Key to display the initial setting screen
for Fn201 (Advanced Autotuning).
Only the moment of inertia calculation can be used.
Press the
1.
Press the
calculation execution screen will be displayed.
Press the
turned ON and the display will change from "BB" to
"RUN."
The moment of inertia is calculated.
Press the
STROKE (travel distance), or press the
negative (-) value is set. Calculation of the moment of
inertia will start.
While the moment of inertia is being calculated, the
set value for Pn103 will flash and "ADJ" will flash
instead of "RUN."
When calculating the moment of inertia is completed,
the display will stop flashing and the moment of iner-
tia will be displayed. The servomotor will remain
ON, but the auto run operation will be stopped tem-
porarily.
Note:
• If the wrong key (i.e.,
for the set STROKE (travel direction), the calcula-
tion will not start.
• If "NO-OP" or "Error" is displayed during opera-
tion, press the
Refer to (2)Failure in Operation and take a correc-
tive action to enable operation.
Operation
or
Key to move
or
Key and set the items in step 3-
Key. The moment of inertia ratio
Key. The servomotor power will be
Key if a positive (+) value is set in
or
Key) is pressed
Key to cancel the function.
Key if a