5 Adjustments
5.4.2 Anti-Resonance Control Adjustment Function Operating Procedure
Step
8
9
10
11
5-28
Display after Operation
Keys
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and
go to step 10.
Select the digit with the
the
or
Press the
Key to save the adjusted settings in the
multi-winding drive unit. "DONE" will flash for
approximately two seconds and "RUN" will be dis-
played.
Press the
control adjustment function. The screen in step 1 will
appear again.
Operation
or
Key, and press
Key to fine-tune the frequency.
Key to complete the anti-resonance
(cont'd)