Alarm Number:
Alarm Name
(Alarm Description)
The SERVOPACK capacity, con-
verter capacity, and the servomo-
tor capacity do not match each
other.
A.040:
Parameter Setting
A fault occurred in the multi-
Error 1
winding drive unit.
(The parameter setting
was out of the setting
The parameter setting is out of
range.)
the setting range.
The electronic gear ratio is out of
the setting range.
The encoder output pulse (Pn212)
A.041:
is out of the setting range and
Encoder Output Pulse
does not satisfy the setting condi-
Setting Error
tions.
The speed of program JOG oper-
ation (Fn004) is lower than the
setting range after having
changed the electronic gear ratio
(Pn20E/Pn210) or the servomo-
tor.
The speed of program JOG oper-
A.042:
ation (Fn004) is lower than the
Parameter
setting range after having
changed the setting of the pro-
Combination Error
gram JOG movement speed
(Pn533).
The moving speed of advanced
autotuning is lower than the set-
ting range after having changed
the electronic gear ratio (Pn20E/
Pn210) or the servomotor.
A.045:
Multi-winding Drive
The connected SERVOPACK is
Unit Parameter Set-
not recognized.
ting Error
For a 4-byte parameter bank, no
registration in two consecutive
A.04A:
bytes for two bank members.
Parameter Setting
The total amount of bank data
Error 2
exceeds 64. (Pn900 × Pn901 >
64)
Detection conditions
If one of the following conditions detected, an alarm occurs.
Pn533 [min
Max Motor Speed [min
Cause
Check the combination of SERVO-
PACK, converter, and servomotor
capacities.
Check the setting ranges of the
parameters that have been changed.
Check the electronic gear ratio. The
ratio must satisfy:
0.001< (Pn20E/Pn210) < 4000.
Check the parameter Pn212.
Check if the detection conditions
are satisfied.
Check if the detection conditions
are satisfied.
Check if the detection conditions
are satisfied.
• Check if the power is supplied to
the SERVOPACK.
• Check the connection of the local
communications cable.
Encoder resolution
Pn20E
-1
] ×
5
Pn210
6 × 10
Encoder resolution
-1
] ×
About 3.66 × 10
Investigative Actions
Select the proper combination of
capacities.
The multi-winding drive unit may
be faulty. Replace the multi-wind-
ing drive unit.
Set the parameter to a value within
the setting range.
Set the electronic gear ratio in the
range: 0.001< (Pn20E/Pn210)
< 4000.
Set Pn212 to a correct value.
*
Decrease the setting of the elec-
tronic gear ratio (Pn20E/Pn210).
*
Increase the setting of the program
JOG movement speed (Pn533).
*
Decrease the setting of the elec-
tronic gear ratio (Pn20E/Pn210).
Change the number of bytes for
bank members to an appropriate
value.
Reduce the total amount of bank
data to 64 or less.
Pn20E
12
Pn210
8.1 Alarm Displays
(cont'd)
Corrective Actions
• Perform the wiring so that the
control power supply to the
multi-winding drive unit and
SERVOPACK is turned ON at the
same time.
• Connect the local communica-
tions cable correctly.