Parameter
Size
No.
2
Input Signal Selection 5
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn511
Setting
Name
Range
0000 to
FFFF
Homing Deceleration Switch Signal Mapping (/DEC)
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
External Latch Signal Allocation (/EXT1)
0
Not active (fixed).
1
Active when CN1-8 input signal is ON (closed).
2
Active when CN1-8 input signal is OFF (open).
External Latch 2 Signal Allocation (/EXT2)
0
Not active (fixed).
1
Active when CN1-12 input signal is ON (closed).
2
Active when CN1-12 input signal is OFF (open).
External Latch 3 Signal Allocation (/EXT3)
0
Not active (fixed).
1
Active when CN1-14 input signal is ON (closed).
2
Active when CN1-14 input signal is OFF (open).
Factory
When
Units
Setting
Enabled
6541
After restart
9.1 List of Parameters
(cont'd)
Classi-
Reference
fication
Section
Setup
3.4.1
9
9-19