9 Appendix
9.1.2 Parameters
Parameter
Size
No.
2
Input Signal Selection 2
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn50B
9-16
Setting
Name
Range
0000 to
FFFF
N-OT Signal Mapping (Reverse run prohibited when OFF (open))
0
Reverse run allowed when CN1-40 input signal is ON (closed).
1
Reverse run allowed when CN1-41 input signal is ON (closed).
2
Reverse run allowed when CN1-42 input signal is ON (closed).
3
Reverse run allowed when CN1-43 input signal is ON (closed) .
4
Reverse run allowed when CN1-44 input signal is ON (closed).
5
Reverse run allowed when CN1-45 input signal is ON (closed).
6
Reverse run allowed when CN1-46 input signal is ON (closed).
7
Reverse run prohibited.
8
Reverse run allowed.
9
Reverse run allowed when CN1-40 input signal is OFF (open).
A
Reverse run allowed when CN1-41 input signal is OFF (open).
B
Reverse run allowed when CN1-42 input signal is OFF (open).
C
Reverse run allowed when CN1-43 input signal is OFF (open).
D
Reverse run allowed when CN1-44 input signal is OFF (open).
E
Reverse run allowed when CN1-45 input signal is OFF (open).
F
Reverse run allowed when CN1-46 input signal is OFF (open).
Reserved (Do not change.)
/P-CL Signal Mapping (Torque Limit when ON (closed))
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/N-CL Signal Mapping (Torque Limit when ON (closed))
0 to F
Same as /P-CL signal mapping
Factory
When
Units
Setting
Enabled
8883
After restart
(cont'd)
Classi-
Reference
fication
Section
Setup
Reference
Section
4.3.2
Reference
Section
4.5.2
Reference
Section
4.5.2