4 Operation

4.6.2 Absolute Data Request (SENS ON Command)

4.6.2

Absolute Data Request (SENS ON Command)

The Turn Encoder Power Supply ON command (SENS_ON) must be sent to obtain absolute data as an output
from the multi-winding drive unit.
The SENS_ON command is sent at the following timing.
Control power supply
ALM signal OFF
(Alarm status)
SENS_ON
(Turn Encoder Power
Supply ON)
PAO
PBO
Servomotor power
Send the SENS_OFF command to turn OFF the control power supply.
4-36
ON
5 seconds max.
OFF
ON (Normal status)
OFF
ON
OFF
Rotational serial data
Undefined
Undefined
60 ms max.
(90 ms typ.)
Approx.
50 ms
15 ms
The servomotor will not be turned ON even if the
SV_ON command is received during this interval.
Incremental
Initial incremental
pulses
pulses
(Phase A)
(Phase A)
Initial incremental
Incremental
pulses
pulses
(Phase B)
(Phase B)
ON
400 ms max.
1 to 3 ms
*
OFF
OFF
OFF
OFF
M-II