YASKAWA Sigma-V Series User Manual page 311

Ac servo drives for use with large-capacity models design and maintenance, multi-winding drive unit rotational motor, mechatrolink-ii communications references, servopack, converter, servomotor
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

9 Appendix
9.1.2 Parameters
Parameter
Size
No.
2
Latch Sequence Signal 1 to 4 Setting
4th
digit
n.
Pn852
2
Latch Sequence Signal 5 to 8 Setting
4th
digit
n.
Pn853
Station Address Monitor
Pn880
2
(for maintenance, read only)
Setting Transmission Byte Monitor [byte]
Pn881
2
(for maintenance, read only)
Transmission Cycle Setting Monitor
Pn882
2
[0.25 μs] (for maintenance, read only)
∗1. For details, refer to the
ual MECHATROLINK-II Commands (Manual No.: SIEP S800000 54).
9-30
Name
3rd
2nd
1st
digit
digit
digit
Latch sequence 1 signal selection.
0
Phase C
1
EXT1 signal
2
EXT2 signal
3
EXT3 signal
Latch sequence 2 signal selection.
0 to 3 Same as latch sequence 1 signal selection.
Latch sequence 3 signal selection.
0 to 3 Same as latch sequence 1 signal selection.
Latch sequence 4 signal selection.
0 to 3 Same as latch sequence 1 signal selection.
3rd
2nd
1st
digit
digit
digit
Latch sequence 5 signal selection
0
Phase C
1
EXT1 signal
2
EXT2 signal
3
EXT3 signal
Latch sequence 6 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
Latch sequence 7 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
Latch sequence 8 signal selection.
0 to 3 Same as latch sequence 5 signal selection.
Σ
-V Series/DC Power Input
Setting
Factory
Units
Range
Setting
0000 to 3333
0000
0000
3333
0000
to
40 to 5FH
17, 32
0 to FFFFH
Σ
Σ
-V Series/
-V Series for Large-Capacity Models User's Man-
When
Classi-
Enabled
fication
Immediately
Setup
Immediately
Setup
0
Immediately
Setup
0
Immediately
Setup
0
Immediately
Setup
(cont'd)
Reference
Section
*1
*1

Advertisement

Table of Contents
loading