Advertisement

5 Adjustments
5.4.2 Anti-Resonance Control Adjustment Function Operating Procedure
Step
6
7
8
9
10
11
5-26
Display after Operation
Keys
Press the
and the flashing of "freq" will stop.
Select the digit with the
the
or
Example of measured waveform
Note: Increase the damping gain from about 0% to
200% in 10% increments while checking the
effect of vibration reduction. If vibration reduc-
tion is still insufficient at a gain of 200%, can-
cel the setting, and lower the control gain by
using a different method, such as one-parame-
ter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and
go to step 10.
Select the digit with the
the
or
Press the
Key to save the adjusted settings in the
multi-winding drive unit. "DONE" will flash for
approximately two seconds and "RUN" will be dis-
played.
Press the
control adjustment function. The screen in step 1 will
appear again.
Operation
Key. The cursor will move to "damp,"
or
Key, and press
Key to set the damping gain.
Error
Error
Error
Torque reference
Torque reference
Torque reference
Positioning completed
Positioning completed
Positioning completed
signal
signal
signal
or
Key, and press
Key to fine-tune the frequency.
Key to complete the anti-resonance
(cont'd)
Ro-
ta-
tion