9 Appendix
9.1.2 Parameters
Parameter
Size
No.
2
Notch Filter Adjustment Switch
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn460
Pn501
2
Zero Clamp Level
Pn502
2
Rotation Detection Level
Pn503
2
Speed Coincidence Signal Output Width
Pn506
2
Brake Reference - Servo OFF Delay Time
Pn507
2
Brake Reference Output Speed Level
Waiting Time for Brake
Pn508
2
Signal When Motor Running
Pn509
2
Instantaneous Power Cut Hold Time
9-14
Setting
Name
Range
0000 to 0101
Notch Filter Adjustment Selection 1
0
Does not adjust 1st step notch filter automatically using utility function.
1
Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0
Does not adjust 2nd step notch filter automatically using utility function.
1
Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
0 to 10000
1 to 10000
0 to 100
0 to 50
0 to 10000
10 to 100
20 to 50000
Factory
When
Units
Setting
Enabled
0101
Immediately
-1
10
Immediately
1 min
-1
20
Immediately
1 min
-1
10
Immediately
1 min
10 ms
0
Immediately
-1
100
Immediately
1 min
10 ms
50
Immediately
1 ms
20
After restart
(cont'd)
Classi-
Reference
fication
Section
Tuning
5.3.1
Setup
Setup
4.7.3
Setup
4.7.5
Setup
4.3.4
Setup
4.3.4
Setup
4.3.4
Setup
4.3.6