YASKAWA Sigma-V Series User Manual page 184

Ac servo drives for use with large-capacity models design and maintenance, multi-winding drive unit rotational motor, mechatrolink-ii communications references, servopack, converter, servomotor
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

 With Determined Vibration Frequency
Step
Display after Operation
1
2
3
4
5
6
7
5.4 Anti-Resonance Control Adjustment Function (Fn204)
Keys
Press the
Key to view the main menu for the
utility function.
Use the
or
select Fn204.
Press the
Key to display the initial setting screen
for tuning mode.
Press the
or
"1."
Press the
Key while "Tuning Mode = 1" is dis-
played. The screen shown on the left will appear and
"freq" will flash.
Example of measured waveform
Select the digit with the
the
or
Press the
Key. The cursor will move to "damp."
Select the digit with the
the
or
Example of measured waveform
Note: Increase the damping gain from about 0% to
200% in 10% increments while checking the
effect of vibration reduction. If vibration reduc-
tion is still insufficient at a gain of 200%, can-
cel the setting, and lower the control gain by
using a different method, such as one-parame-
ter tuning.
Operation
Key to move through the list,
Key and set the tuning mode
Ro-
ta-
Error
Error
Error
tion
Torque reference
Torque reference
Positioning completed
Positioning completed
Positioning completed
signal
signal
signal
or
Key, and press
Key to adjust the frequency.
or
Key, and press
Key to adjust the damping gain.
Ro-
ta-
tion
Error
Error
Error
Torque reference
Torque reference
Torque reference
Positioning completed
Positioning completed
Positioning completed
signal
signal
signal
5
5-27

Advertisement

Table of Contents