Auerswald COMpact 5200 Advanced Information page 769

Voip pbx for medium sized business
Hide thumbs Also See for COMpact 5200:
Table of Contents

Advertisement

Relais de commutation IP
Le système est maître
The available relays on an IP switch relay can also be toggled without
affecting the PBX. In some situations, e.g. if the PBX is switched off at the
switching point, the PBX cannot identify the state of the relay.

The PBX restores the relay to the last state it was able to identify after
it is rebooted.
Commande d'arrêt
Requirements:
the relay must have been set up

The PBX will switch off relays with the operating modes Light, Door
opener, Alarm and PC relay after the specified switching duration.

The hold time of the relay will be used. The PBX does not actively
switch off the relay.
Note: As a a pre-requisite, off control must be supported by the relay (for
some relays, e. g. the a/b Switching Modules, switching off cannot be
controlled).
Plages horaires
Specifies after how many seconds the PBX will switch off the relay. Possible
entries: 0 to 6000 (0 only for manual relays).
Notes:
The switching duration is used for relays with the operating modes Light,
Door opener, Alarm, PC relay and Manual relay.
COMpact 5200/5200R/5500R - Firmware V7.2 - Advanced Information V04 07/2018
Settings – Périphériques
Relais (actionneurs)
769