5
Commands by Subsystem
:TRIGger:LIN:SYNCbreak
Command Syntax
:TRIGger:LIN:SYNCbreak <value>
<value> ::= integer = {11 | 12 | 13}
The :TRIGger:LIN:SYNCbreak command sets the length of the LIN sync
break to be greater than or equal to 11, 12, or 13 clock lengths. The sync
break is the idle period in the bus activity at the beginning of each packet
that distinguishes one information packet from the previous one.
Query Syntax
:TRIGger:LIN:SYNCbreak?
The :TRIGger:LIN:STANdard? query returns the current LIN sync break
setting.
Return Format
<value><NL>
<value> ::= {11 | 12 | 13}
See Also
•
•
•
•
468
(see
page
658)
"Introduction to :TRIGger Commands"
":TRIGger:MODE"
on page 417
":TRIGger:LIN:SIGNal:DEFinition"
":TRIGger:LIN:SOURce"
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide
on page 411
on page 612
on page 466