5.6.3 Cardcage Intake Fans - Top (2 fans)

The cardcage intake fans are located on top of the
cardcage. These fans draw in air responsible for
cooling the cardcage electronics. Both fans are
plugged into the EVB board and can be replaced
individually.
(Estimated Replacement Time: 4 minutes per
fan)
1. Remove the front top lid. Refer to
Top Lid, on page 5-6.
2. Remove the high security lid. Refer to
High Security Lid, on page 5-7.
3. Disconnect the two fan harnesses from the
EVB board. (Figure 5-19)
4. Cut the cable ties and remove the fans from
the rubber isolators.
CP4230 Service Manual
020-100622-04 Rev. 1 (05-2016)
5.4.2 Front
5.4.3
Section 5: Parts and Module Replacement
Figure 5-19 Cardcage Intake Fans
5-15