Figure 3-3. Flowchart Of Menu-Driven Firmware - Thermo Scientific 5028i Instruction Manual

Continuous particulate monitor
Table of Contents

Advertisement

Range
Integration Time
Conc Units
Integration Time A
PM Range
Integration Time B
PMb Range
Set Custom Ranges
Thermo Fisher Scientific
conditions, sample conditions, and mass sensor data. From the Run
screen, the Main Menu can be displayed by pressing
Menu contains a list of submenus. Each submenu contains related
instrument settings. This chapter describes each submenu and screen in
detail. Refer to the appropriate sections for more information.
24Hr Average
Calibration Factors
PM
PM Bkg
Measurement Mode
PMb
PMb Bkg
Set Flow/Pump
Start Time
PM Coef
Set Heater
PMb Coef
Heater
Heater B
Filter Tape Control
Channel A
Channel B
Detectors
Volumetric Conditions
Datalogging Settings
Communication Settings
I/O Config
Screen Contrast
Service Mode (on/off)
Data/Time
TimeZone
Figure 3–3. Flowchart of Menu-Driven Firmware
Power-up
Screen
Self Test
Screen
Run Screens
Main Menu
Instrument Controls
Diagnostics
Program Versions
Voltages
Motherboard
Interface Board
Control
I/O Board
Off
Detector Board
RH
RH/Temperature
Temp
Ambient RH
RH Threshold
Sample RH
Temp Threshold
Sample RH B
Ambient Temp
Control
Flow Temp
Off
Flow Temp B
RH
Board Temp
Temp
Pressure/Vacuum
RH Threshold
Barometric
Temp Threshold
Vacuum
Flow
Vacuum B
Flow B
Manual
Flow
Bench
Flow A
Tape
Mass Limit
Flow B
Next Time
Detector Status
Period
Mass
Counter
Alpha
Beta
Manual
Beta Corr
Bench
Beta Zero
Tape
Detector Status B
Mass Limit
Mass
Next Time
Alpha
Period
Beta
Counter
Beta Corr
Beta Zero
A Auto Adjust
CRn
B Auto Adjust
Analog Input Readings
IN 1-8
Temperature
Analog Input Voltages
Pressure
Analog In 1-8
Temperature B
Digital Inputs
Pressure B
Input 1-16
Relay States
Select SREC/LREC
Output 1-10
View logged data
Test Analog Outputs
Erase log
ALL
Select Content
Voltage Channel 1-6
Commit Content
Current Channel 1-6
Instrument Configuration
Reset to Default content
I/O Expansion Board
Configure Datalogging
Detector
Detector B
Serial Settings
Contact Info
Instrument ID
Geysitech Serial No
Communication Protocol
Streaming data Config
TCP/IP Settings
Output Relay Settings
1-10
Digital Input Settings
1-16
Analog Output Config
Allow Over/Under
All Voltage Channels
All Current Channels
Voltage Channel 1-6
Current Channel 1-6
Analog Input Config
1-8
Alarms
Service
Alarms Detected
RH/Temperature Calibration
Instrument Alarms
Ambient Temp
Filter Tape Counter
Flow Temp
Filter Tape Change
Flow Temp B
Bench
Ambient RH
Heater Power
Pres/Vacuum Calibration
Motherboard Status
Baro Pres
Interface Status
Vac/Flow
I/O EXP Status
Vac/Flow B
Filter B Tape Counter
Flows Calibration
Filter B Tape Change
Flow Span
Bench B
Flow Span B
Heater B Power
Mass Calibration
Detector Alarms
Mass Calibration A
Board Status
Thermal Coefficient
Board Status B
Vacuum Coefficient
Alpha
Baro Coefficient
Alpha B
Mass Coefficient
Beta
Alpha EFF Coefficient
Beta B
Mass Calibration B
RH/Temperature Alarms
Thermal Coefficient
Ambient RH
Vacuum Coefficient
Sample RH
Baro Coefficient
Sample RH B
Mass Coefficient
Ambient Temp
Alpha EFF Coefficient
Flow Temp
Detectors Calibration
Flow Temp B
Detectors Calibration
Board Temp
Auto
Pressure/Vacuum Alarms
Manual
Baro Press
Detectors Calibration B
Vacuum
Auto
Vacuum B
Manual
Flow
Analog Out Calibration
Flow B
Voltage Channel 1-6
Flow Alarms
Current Channel 1-6
Flow
Analog Input Calibration
Flow B
Input Channel 1-8
Conc Alarms
Language
Avg PM
English
Avg PMb
Chinese
Inst PM
Display Pixel test
Inst PMb
Restore User Defaults
Restore Factory Defaults
Model 5028i Instruction Manual
Operation
Firmware Overview
. The Main
Password
Set Password
Lock Password
Change Password
Remove Password
Unlock Password
3-5