At+Cfun Set Phone Functionality - SimCom SIM7000 Series At Command Manual

Hide thumbs Also See for SIM7000 Series:
Table of Contents

Advertisement

3GPP TS 27.007
[13]

3.2.19 AT+CFUN Set Phone Functionality

AT+CFUN Set Phone Functionality
Test Command
Response
AT+CFUN=?
+CFUN: (list of supported <fun>s),(list of supported <rst>s)
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
See Write Command
Read Command
Response
AT+CFUN?
+CFUN: <fun>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
See Write Command
Write Command
Response
AT+CFUN=<fun
OK
>[,<rst>]
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<fun>
<rst>
Parameter Saving
-
Mode
Max
Response
10s
Time
Reference
Note
SIM7000 Series_AT Command Manual_V1.03
0
Minimum functionality
1
Full functionality (Default)
4
Disable phone both transmit and receive RF circuits.
5
Factory Test Mode
6
Reset
7
Offline Mode
0
Do not Reset the MT before setting it to <fun> power level.
1
Reset the MT before setting it to <fun> power level.