8.2.3
AT+CIPSEND Send Data Through TCP or UDP Connection
AT+CIPSEND Send Data Through TCP or UDP Connection
Test Command
Response
AT+CIPSEND=?
1) For single IP connection (+CIPMUX=0)
+CIPSEND: <length>
OK
2) For multi IP connection (+CIPMUX=1)
+CIPSEND: (0-7),<length>
OK
Parameters
See Write Command
Read Command
Response
1) For single IP connection (+CIPMUX=0)
AT+CIPSEND?
+CIPSEND: <size>
OK
2) For multi IP connection (+CIPMUX=1)
+CIPSEND: <n>,<size>
OK
Parameters
<n>
<size> A numeric parameter which indicates the data length sent at a time
Write Command
Response
1) If single IP
This Command is used to send changeable length data
connection
If single IP is connected (+CIPMUX=0)
(+CIPMUX=0)
If connection is not established or module is disconnected:
AT+CIPSEND=<
If error is related to ME functionality:
length>
+CME ERROR <err>
If sending is successful:
2) If multi IP
When +CIPQSEND=0
connection
SEND OK
(+CIPMUX=1)
When +CIPQSEND=1
AT+CIPSEND=<
DATA ACCEPT: <length>
n>[,<length>]
If sending fails:
SEND FAIL
If multi IP connection is established (+CIPMUX=1)
If connection is not established or module is disconnected:
If error is related to ME functionality:
+CME ERROR <err>
SIM7000 Series_AT Command Manual_V1.03
A numeric parameter which indicates the connection number
125
Smart Machine Smart Decision
2018-05-08