Advertisement

Parameters
See Write Command
Read Command
Response
AT+SLEDS?
+SLEDS: <mode>,<timer_on>,<timer_off>
OK
Parameters
See Write Command
Write Command
Response
AT+SLEDS=<m
OK
ode>,<timer_on>
ERROR
,<timer_off>
Parameters
<mode>
<timer_on>
40-65535(ms)
<timer_off>
40-65535(ms)
Parameter Saving
-
Mode
Max
Response
-
Time
Reference
Note
The default value is :
<mode>,<timer_on>,<timer_off>
1,64,800
2,64,3000
3,64,300

5.2.14 AT+CNETLIGHT Close the Net Light or Open It to Shining

AT+CNETLIGHT Close the Net Light or Open It to Shining
Test Command
Response
AT+CNETLIGH
+CNETLIGHT: (0,1)
T=?
OK
SIM7000 Series_AT Command Manual_V1.03
1 Set the timer period of net light while SIM7000 series does not
register to the network
2 Set the timer period net light while SIM7000 series has already
registered to the network
3 Set the timer period net light while SIM7000 series is in the state of
PPP communication
Timer period of "LED ON" in decimal format which range is 0 or
Timer period of "LED OFF" in decimal format which range is 0 or
Smart Machine Smart Decision