At+Clck Facility Lock - SimCom SIM7000 Series At Command Manual

Hide thumbs Also See for SIM7000 Series:
Table of Contents

Advertisement

Max Response
20s
Time
Reference
Note
3GPP TS 27.007
[13]
3.2.7

AT+CLCK Facility Lock

AT+CLCK Facility Lock
Test Command
Response
+CLCK: (list of supported <fac>s)
AT+CLCK=?
OK
Parameters
See Write Command
Write Command
Response
This Command is used to lock, unlock or interrogate a ME or a network
AT+CLCK=<fac>
facility <fac>. Password is normally needed to do such actions. When
,<mode>[,<passw
querying the status of a network service (<mode>=2) the response line for
d>[,<class>]]
'not active' case (<status>=0) should be returned only if service is not
active for any <class>.
If <mode>≠2 and Command is successful
OK
If <mode>=2 and Command is successful
+CLCK: <status>[,<class1>[<CR><LF>+CLCK:
<status>,<class2>[...]]
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<fac>
SIM7000 Series_AT Command Manual_V1.03
"AB"
All Barring services(only for <mode>=0)
"AC"
All inComing barring services(only for <mode>=0)
"AG"
All outGoing barring services(only for <mode>=0)
"AI"
BAIC (Barr All Incoming Calls)
"AO"
BAOC (Barr All Outgoing Calls)
"IR"
BIC-Roam (Barr Incoming Calls when Roaming
outside the home country)
"OI" BOIC (Barr Outgoing International Calls)
"OX" BOIC-exHC (Barr Outgoing International Calls except
to Home Country)