<HTTPParamValue>
Parameter Saving
NO_SAVE
Mode
SIM7000 Series_AT Command Manual_V1.03
(Mandatory Parameter) HTTP client URL
"http://'server'/'path':'tcpPort' "
"server": FQDN or IP-address
"path": path of file or directory
"tcpPort": default value is 80.
"UA"
Refer to "IETF-RFC 2616".
The user agent string which is set by the
application to identify the mobile. Usually this
parameter is set as operation system and software
version information.
"PROIP"
Default value is "SIMCom_MODULE".
"PROPORT"
The IP address of HTTP proxy server
"REDIR"
The port of HTTP proxy server
This flag controls the redirection mechanism of the
SIM800 when it is acting as HTTP client
(numeric). If the server sends a redirect code
(range 30x), the client will automatically send a
new HTTP request when the flag is set to (1).
"BREAK"
Default value is 0 (no redirection).
Parameter for HTTP method "GET", used for
"BREAKEND"
resuming broken transfer.
Parameter for HTTP method "GET", used for
resuming broken transfer. which is used together
with "BREAK",
If the value of "BREAKEND" is bigger than
"BREAK", the transfer scope is from "BREAK" to
"BREAKEND".
If the value of "BREAKEND" is smaller than
"BREAK", the transfer scope is from "BREAK" to
"TIMEOUT"
the end of the file.
If both "BREAKEND" and "BREAK" are 0, the
resume broken transfer function is disabled.
HTTP session timeout value, scope: 30-1000
second.
Default value is 120 seconds.
HTTP Parameter value. Type and supported
"CONTENT"
content depend on related <HTTPParamTag>.
Used to set the "Content-Type" field in HTTP
"USERDATA"
header.
User data
HTTP Parameter value.Type and supported content
depend on related <HTTPParamTag>.
154
Smart Machine Smart Decision
2018-05-08
Need help?
Do you have a question about the SIM7000 Series and is the answer not in the manual?