At+Cpsi Inquiring Ue System Information - SimCom SIM7000 Series At Command Manual

Hide thumbs Also See for SIM7000 Series:
Table of Contents

Advertisement

<AcT-type>
<Requested_eDRX_value> Requested eDRX value. 4 bit format.
Parameter Saving
AUTO_SAVE
Mode
Max
Response
-
Time
Reference
Note

5.2.22 AT+CPSI Inquiring UE system information

AT+CPSI Inquiring UE system information
Test Command
Response
AT+CPSI=?
OK
Read Command
If camping on a gsm cell:
AT+CPSI?
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<LA
C>,<Cell ID>,<Absolute RF Ch Num>,<RxLev>,<Track LO Adjus
t>,<C1-C2>
OK
If camping on a CAT-M or NB-IOT cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<TAC>
,<SCellID>,<PCellID>,<Frequency Band>,<earfcn>,<dlbw>,<ulbw>,<
RSRQ>,<RSRP>,<RSSI>,<RSSNR>
OK
If no service:
+CPSI: NO SERVICE,Online
OK
If failed:
+CME ERROR: <err>
Parameters
<System Mode>
SIM7000 Series_AT Command Manual_V1.03
4 CAT-M
5 NB-IoT
"0000"-"1111"
The Requested_eDRX_value is the value of cycle length, separately
means
5.12,10.24,20.48,40.96,61.44,81.92,102.40,122.88,143.36,163.84,327.
68,655.36,1310.72,2621.44,5242.88,10485.76.(seconds)
System mode.
"NO SERVICE"
"GSM"
"LTE CAT-M1"
Smart Machine Smart Decision
98
2018-05-08

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIM7000 Series and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF