18.2.5 AT+CASEND Send data via an established connection

AT+CASEND Send data via an established connection
Test Command
Response
AT+CASEND=?
+CASEND: (range of supported <cid>s),( range of supported <datalen>)
OK
Parameters
See Write Command
Write Command
Response
AT+CASEND=<ci
+CASEND: <cid>,<datalen>
d>,<datalen>
........ //Input data
OK
+CASEND: <cid>,<result>,<sendlen>
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<cid>
<datalen> Requested number of data bytes to be transmitted
<sendlen> Data bytes that has been sent successfully
<result> see AT+CAOPEN
Parameter
Saving
NO_SAVE
Mode
Max
Response
-
Time
Reference
Note

18.2.6 AT+CARECV Receive data via an established connection

AT+ CARECV Receive data via an established connection
Test Command
Response
+CARECV: (range of supported <cid>s),( range of supported <readlen>)
AT+CARECV=?
OK
Parameters
See Write Command
Write Command
Response
AT+CARECV=<ci
+CARECV: <cid>,<recvlen>
d>,<readlen>
.......
OK
If error is related to ME functionality:
SIM7000 Series_AT Command Manual_V1.03
see AT+CACID
//output data