Main Menu
Blower Unit
Replacement
1.
Remove the spare tire (refer to Owner's manual).
2.
Remove the spare tire holder.
CORROSION RESISTANT BOLT
6 x 1.0 mm
9.8 N-m (1.0 kgf-m, 7.2 Ibf-ft)
3.
Disconnect the cables from the battery, loosen the
hold-down bracket nuts, and remove the hold-
down bracket. Then, remove the battery.
HOLD-DOWN
BRACKET
Table of Contents
SPARE TIRE
HOLDER
BATTERY
4.
Remove the under-hood relay box A and the water
drain duct. Disconnect the connectors from the
blower motor, power transistor and recirculation
control motor.
CORROSION RESISTANT BOLT
6 x 1.0 mm
9.8 N-m (1.0 kgf-m, 7.2 Ibf-ft)
UNDER-HOOD
RELAY
BOX A
BLOWER MOTOR,
POWER TRANSISTOR,
and RECIRCULATION CONTROL
MOTOR CONNECTORS
5.
Remove the mounting bolts, then remove the blower
unit.
CORROSION RESISTANT BOLT
6 x 1.0 mm
9.8 N-m (1.0 kgf-m, 7.2 Ibf-ft)
6.
Install the blower unit in the reverse order of
removal, then make sure it runs and doesn't leak
any air.
WATER
DRAIN
DUCT
6 x 1.0 mm
9.8 N-m (1.0 kgf-m, 7.2 Ibf-ft)
BLOWER
UNIT