6
Diagnostics and monitoring
6.1
Diagnostics and monitoring with SINAMICS SDI Status
The SINAMICS S200 converter product line is designed with a SINAMICS SDI (Smart Drive Interface) Status panel on the front
of the converter.
①
Cover*
②
6-digit 7-segment display
③
LED display
④
Function buttons
* Open the cover gently from the lower right corner.
You can use the SDI Status panel for the following operations:
•
Monitoring
The SINAMICS SDI Status enters the monitoring mode when the servo state changes from OFF to ON. In this mode, it
displays the actual speed, actual torque, actual position, actual DC link voltage, and position following error. You can
press the DOWN button for navigating to the next item.
•
Diagnosis
The SINAMICS SDI Status enters the diagnosis mode when a new fault, alarm, or safety message appears. You can press
the OK button to acknowledge the faults after eliminating the causes. You can press the M button to switch between the
monitoring mode and the diagnosis mode.
•
Converter restart
You can press the key combination of the M button and the OK button for four seconds to restart the converter.
30
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
A5E52388930A AA, 07/2023