KX080-4, WSM
(5) Blower Switch
Voltage check
1. Disconnect the blower switch connector.
2. Turn the key switch to the RUN position.
3. Measure the voltage based on the table below.
Mea-
Connector terminal
sure-
name (+ terminal
ment
side)
Blower switch
(a)
connector
Blower switch
(b)
connector
Regular: 12V
Irregular: Large discrepancy from 12V
(1) Control panel
1. Turn the key switch to the STOP position.
2. Remove the control panel from the machine and test the blower
switch independently.
(1) Control panel
5-S26
Pin
Connector terminal
No.
name (- terminal side)
Blower switch
<6>
connector
<6>
Body GND
(2) Blower switch connector
RY9212158CAS0001US0
(2) Blower switch
RY9212158CAS0002US0
KiSC issued 08, 2015 A
CABIN
Pin
No.
<3>
–