1. Testing the accelerator sensor
[Measurement Conditions]
1. Key switch : OFF
2. Disconnect the accelerator sensor from the machine and test it
separately.
Factory specification
Accelerator sensor 4 to 8
Accelerator sensor 7 to 8
Accelerator sensor 4 to 7
(a) Accelerator Dial Terminal
Numbers
2. Settings after replacing device
1. Make AI settings.
(1) AI Set
AUX Set
AUX2/Thumb Set
1. Delete failure record
1. While in the service/dealer mode, select Delete Fail Record and
delete the record.
2. After deleting the record, start the engine again and check to
make sure the warning is not shown on the meter panel.
(1) No Fail Record
4-S76
ELECTRICAL SYSTEM
Min.
Max.
1 kΩ ± 10 %
1 kΩ ± 10 %
720 Ω
380 Ω
380 Ω
720 Ω
RY9212148ELS0108US0