Charging System Errors - Kubota KX080-4 Workshop Manual

Hide thumbs Also See for KX080-4:
Table of Contents

Advertisement

KX080-4, WSM

(2) Charging System Errors

[A] Checking the Meter Panel
1. Information displayed on the meter panel
1. Check whether or not the warning lamp (a) on the panel is
blinking red.
2. Check whether the charging lamp (b) is lit in red or off.
[Reason error screen displayed]
• Alternator faulty
• Fan belt loose/off
• Break in the harness
• Fuse blown (10A)
(1) Charging Sys Err
[Test Conditions]
1. Key switch : ON
(a) If the charging lamp is lit : caused by a short
(b) If the charging lamp is off : caused by break in wiring
2. Reading the failure history
1. Select the failure history read mode.
2. Read the failure history and check the date (y/m/d) and hour
meter of the last occurrence.
Ex.) The last failure record was February 6, 2009 at 37 hours.
(a) Failure
(b) Number of Failure
3. Tester mode
1. Select the tester mode.
2. Check the operation of the charge according to the table below.
Regu-
Charge
lar
Key Off
Off
Key On
Lit
Key Start
Off
(1) Engine Speed
Battery V
Oil SW
Charging
Starter
4-S56
ELECTRICAL SYSTEM
(a) Warning Lamp
(b) Charging Lamp
RY9212148ELS0078US0
RY9212148ELS0079US0
(c) The Last Breakdown Date (y/m/d)
and Hour Meter.
RY9212032ELS0001US0
When
When
Charge
cut off
shorted
Off
Off
Off
RY9212148ELS0080US0
Charge
Off
Lit
Lit
KiSC issued 08, 2015 A

Advertisement

Table of Contents
loading