Fuel Sensor Errors - Kubota KX080-4 Workshop Manual

Hide thumbs Also See for KX080-4:
Table of Contents

Advertisement

KX080-4, WSM

(3) Fuel Sensor Errors

[A] Checking the Meter Panel
1. Information displayed on the meter panel
Check whether or not the warning lamp (a) on the panel is
blinking red.
[Reason error screen displayed]
• Connector disconnected
• Break in the harness
(1) Fuel Sensor Err
[Test Conditions]
1. Key switch : ON
(a) If the fuel level is at the top : caused by a short
(b) If the fuel level is blank : caused by a break
2. Reading the failure history
1. Select the failure history read mode.
2. Read the failure history and check the date (y/m/d) and hour
meter of the last occurrence.
Ex.) The last failure record was February 6, 2009 at 37 hours.
(a) Failure
(b) Number of Failure
3. Tester mode
1. Select the tester mode.
2. Start the engine.
3. Check the display for the voltage and resistance of the fuel
based on the following table.
When cut off
When shorted
(1) Water Temp.
Fuel
Refueling SW
4-S60
ELECTRICAL SYSTEM
(a) Warning Lamp
RY9212148ELS0084US0
RY9212148ELS0085US0
(c) The Last Breakdown Date (y/m/d)
and Hour Meter.
RY9212032ELS0001US0
Fuel voltage
Resistance
5.00 V
218 Ω
0.00 V
RY9212148ELS0086US0
0 Ω
KiSC issued 08, 2015 A