Kubota KX080-4 Workshop Manual page 351

Hide thumbs Also See for KX080-4:
Table of Contents

Advertisement

KX080-4, WSM
Scre
en
Content displayed
No.
ECU (main)
Ver
24
Rev
Serial No.
ECU (AS)
Ver
25
Rev
Serial No.
[B] Retrieve Fail Record
• Checks the record of past failures.
[C] Delete Fail Record
• Deletes the record of past failures.
Description/std. value
• Program version
• Program creation date (Y/M/D)
• Serial no. (different number each machine)
• Program version
• Program creation date (Y/M/D)
• Serial no. (different number each machine)
1. Select Diagnosis → Retrieve Fail Record.
2. If there are more than one failure records, you can toggle the
display each time you press switch 2 or 3.
[Display when fail record exists]
(1) Content of Failure detected by the
ECU (main or meter or AS) that
detected it
(2) Number of occurrences (1 to 255)
[Display when no fail record exists]
1. Select Diagnosis → Delete Fail Record.
[Display when fail record deleted]
IMPORTANT
• Even when fail records are deleted, they are still recorded
in the all fail record.
4-S20
ELECTRICAL SYSTEM
Notes
Only on RX series (Japan)
RY9212148ELS0029US0
(3) Date and hour meter of initial
occurrence and date and hour
meter of last occurrence
RY9212148ELS0030US0
RY9212148ELS0031US0
RY9212148ELS0032US0
KiSC issued 08, 2015 A