Kubota KX080-4 Workshop Manual page 388

Hide thumbs Also See for KX080-4:
Table of Contents

Advertisement

KX080-4, WSM
[B] Inspecting each Device Visually and Physically
[C] Testing with a Circuit Tester
(a) Meter panel connector
• If connectors (b) (c) are removed, the engine will not start.
1. Checking fuses
Check whether the alternator fuse (10A) is blown.
2. Causes when a break in wiring
[Test Conditions]
1. Key switch : OFF
2. The alternator connector is disconnected.
3. There is a break somewhere in the wiring.
Pull on the harness and make sure the connector/harness does
not come off. (pull with a max of 3 kgf (30 N, 7 lbf) of force) If it
comes off, plug the connector back in securely and check the
operation of the charging switch again in the tester mode.
3. Causes when a short
[Test Conditions]
1. Key switch : OFF
2. The alternator connector wire is pinched against or touching the
body.
If the insulation is damaged, repair it properly and check the
operation of the charging switch again in the tester mode.
(b) Engine (open) connector
(c) Main (open) connector
4-S57
ELECTRICAL SYSTEM
RY9212001ELS0064US0
RY9212148ELS0081US0
RY9212148ELS0082US0
(d) Alternator connector
RY9212148ELS0149US0
KiSC issued 08, 2015 A

Advertisement

Table of Contents
loading