(I) Multipurpose Mode
• Enabling the multi-purpose switch function on machines equipped with AUX1 and AUX2 makes 10 modes
available for use.
• Depending on the selected mode, it becomes necessary to add equipment to the machine, such as ON/OFF
switches, solenoid valves, wire harness, hydraulic hoses, etc.
• The multi-purpose switch allows you to control added solenoid valves and to operate hydraulic devices.
(a) Position of Connector for Operating Added Solenoid Valve
1. Select Setting → Model Set.
2. Make sure the multi-purpose specification is set to "YES."
IMPORTANT
• If the multi-purpose specification is set to "NO," the
multi-purpose mode will not work, so select "YES" and
redo the setting.
3. Select Setting → Others → Multi-purpose mode.
4. Enter the number of the mode you wish to use.
5. Press SW5 to make the setting.
• Available mode numbers: 00 to 10
Mode number when shipped: 00
(Multi-purpose switch function disabled and AUX2 hold function
disabled)
IMPORTANT
• Available from serial number: 030546
(1) Multi-purpose connector
Pin No.
<1>
<2>
4-S29
ELECTRICAL SYSTEM
RY9212148ELS0014US0
RY9212148ELS0048US0
Terminal
Max rated amperage
+ Terminal
1 A
- Terminal
RY9212148ELS0049US0
KiSC issued 08, 2015 A